HS2214ECB61H Renesas Electronics America, HS2214ECB61H Datasheet - Page 23

no-image

HS2214ECB61H

Manufacturer Part Number
HS2214ECB61H
Description
DEV EMULATOR PCB ADAPTOR
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HS2214ECB61H

Accessory Type
User Interface Cable
For Use With/related Products
H8S/2214
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
1. When using the E6000 emulator for the H8S/2214 series, turn on the emulator according to the
2. Verify the user system interface cable connections by accessing the external memory and ports
3. The emulator connected to this user system interface cable supports two kinds of clock sources
procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE).
to check the bus states of the pins with the MEMORY_FILL command (emulator command). If
an error is detected, recheck the soldered IC socket and the location of pin 1.
as the MCU clock: an emulator internal clock and an external clock on the user system. For
details, refer to the Emulator Supplementary Information (HS2214EPI61HE).
 To use the emulator internal clock
 To use the external clock on the user system
Figure 11 shows the oscillator circuit on the user system interface cable.
Select the clock in the emulator station as the system clock (φ), by using the CLOCK
command (emulator command).
Supply the external clock from the user system to the emulator. Connect a crystal oscillator
to the EXTAL and XTAL terminals for the system clock (φ). Select the external clock as the
system clock (φ), by using the CLOCK command (emulator command). For details, refer to
section 16, Clock Pulse Generator, in the H8S/2214 Series Hardware Manual.
EXTAL
R1 1 M
Section 4 Verifying Operation
HCU04
XTAL
R2 270
Figure 11 Oscillator Circuit
HCU04
HCU04
To E6000 emulator
17

Related parts for HS2214ECB61H