EVAL-AD9830EBZ Analog Devices Inc, EVAL-AD9830EBZ Datasheet - Page 2

BOARD EVALUATION AD9830

EVAL-AD9830EBZ

Manufacturer Part Number
EVAL-AD9830EBZ
Description
BOARD EVALUATION AD9830
Manufacturer
Analog Devices Inc
Datasheets

Specifications of EVAL-AD9830EBZ

Main Purpose
Timing, Direct Digital Synthesis (DDS)
Utilized Ic / Part
AD9830
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Secondary Attributes
-
Embedded
-
Primary Attributes
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
EVAL-AD9830EB
Link and Switch Options
There are five link options which must be set for the required operating setup before using the evaluation board. The functions
of these options are outlined below.
Link No.
LK1
LK2
LK3
LK4
LK5
Function
The PSEL1 input can be controlled by the user via a BNC connector or, alternatively, by switch SW.
When LK1 is arranged so that PSEL1 is connected to SW, the user can control the PSEL1 signal using the
double throw switch.
Alternatively, PSEL1 can be tied to a BNC connector by altering LK1 so that the user can provide the PSEL1
control from a logic source.
The PSEL0 input can be controlled by the user via a BNC connector or, alternatively, by switch SW.
When LK2 is arranged so that PSEL0 is connected to SW, the user can control the PSEL0 signal using the
double throw switch.
Alternatively, PSEL0 can be tied to a BNC connector by altering LK2 so that the user can provide the PSEL0
control from a logic source.
The FSELECT input can be controlled by the user via a BNC connector or, alternatively, by switch SW.
When LK3 is arranged so that FSELECT is connected to SW, the user can control the FSELECT signal using
the double throw switch.
Alternatively, FSELECT can be tied to a BNC connector by altering LK3 so that the user can provide the
FSELECT control from a logic source.
LK4 is used to place the AD9830 in sleep mode.
When LK4 is connected so that
AD9830's internal clocks, REFOUT and the DAC are disabled.
When LK4 is connected so that
The reference to the AD9830 can be provided by the on-board reference, which is available at REFOUT, or an
external reference of nominal value 1.21 V can be used. When LK5 is closed, the on-board reference is used.
When this link is opened, REFIN is disconnected from REFOUT and the reference can be provided by the
user via a BNC connector.
SLEEP
SLEEP
is tied to DGND, the AD9830 is placed in sleep mode whereby the
is tied to DVDD, the AD9830 is powered up.
- 2 -
REV 0