G6KU-2G-Y DC5 Omron, G6KU-2G-Y DC5 Datasheet - Page 4

RELAY LOW SIGNAL SMD

G6KU-2G-Y DC5

Manufacturer Part Number
G6KU-2G-Y DC5
Description
RELAY LOW SIGNAL SMD
Manufacturer
Omron
Series
G6Kr
Datasheets

Specifications of G6KU-2G-Y DC5

Coil Type
Latching, Single Coil
Coil Current
21.1mA
Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Voltage
5VDC
Control On Voltage (max)
3.75 VDC
Mounting Type
Surface Mount
Termination Style
J Lead
Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Coil Resistance
237ohm
Contact Form
DPDT (2 Form C)
Contact Rating (current)
1A
Switching Voltage
125VAC, 60VDC - Max
Turn On Voltage (max)
3.75 VDC
Turn Off Voltage (min)
-
Features
-
Contact Material
Silver (Ag), Gold (Au)
Operate Time
3ms
Release Time
3ms
Coil Power
100 mW
Operating Temperature
-40°C ~ 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6KU-2G-YDC5
G6KU2GYDC5
G6K
Engineering Data
4
Shock Malfunction
Shock direction
Maximum Switching Power
Endurance
Conditions:
DC resistive load
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Shock is applied in ±X, ±Y, and ±Z di-
rections three times each with and with-
out energizing the Relays to check the
number of contact malfunctions.
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Switching voltage (V)
AC resistive load
Switching current (A)
Not
energized
Unit: m/s
Sample: G6K-2G
Number of Relays: 10
Energized
2
Note: The maximum coil voltage refers to the maxi
Electrical Endurance
(with Must Operate and Must Re
lease Voltage) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Maximum Coil Voltage
Operating frequency (x10 operations)
Note: The tests were conducted at an
Must operate
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
mum value in a varying range of operating
power voltage, not a continuous voltage.
Must release
ambient temperature of 23˚C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
3
Must operate voltage
Must release voltage
Electrical Endurance
(Contact Resistance) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Switching Current
Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Operating frequency (x10
Note: The tests were conducted at an
Switching frequency: 1,800 operations/h
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Contact resistance
ambient temperature of 23˚C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
3
operations)
NO
contact
NC
contact
G6K