C8051F341-GQ Silicon Laboratories Inc, C8051F341-GQ Datasheet - Page 234

IC 8051 MCU FLASH 32K 48TQFP

C8051F341-GQ

Manufacturer Part Number
C8051F341-GQ
Description
IC 8051 MCU FLASH 32K 48TQFP
Manufacturer
Silicon Laboratories Inc
Series
C8051F34xr
Datasheets

Specifications of C8051F341-GQ

Program Memory Type
FLASH
Program Memory Size
32KB (32K x 8)
Package / Case
48-TQFP, 48-VQFP
Core Processor
8051
Core Size
8-Bit
Speed
48MHz
Connectivity
EBI/EMI, SMBus (2-Wire/I²C), SPI, UART/USART, USB
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
40
Ram Size
2.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 20x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
C8051F3x
Core
8051
Data Bus Width
8 bit
Data Ram Size
3.25 KB
Interface Type
I2C/SMBus/SPI/UART/USB
Maximum Clock Frequency
48 MHz
Number Of Programmable I/os
40
Number Of Timers
4
Operating Supply Voltage
2.7 V to 5.25 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
KSK-SL-F34X, KSK-SL-TOOLSTICK, PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F340DK
Minimum Operating Temperature
- 40 C
On-chip Adc
17-ch x 10-bit
No. Of I/o's
40
Ram Memory Size
2304Byte
Cpu Speed
48MHz
No. Of Timers
4
Rohs Compliant
Yes
Package
48TQFP
Device Core
8051
Family Name
C8051F34x
Maximum Speed
48 MHz
Data Rom Size
128 B
A/d Bit Size
10 bit
A/d Channels Available
17
Height
1 mm
Length
7 mm
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.7 V
Width
7 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1748 - ADAPTER TOOLSTICK FOR C8051F34X770-1006 - ISP 4PORT FOR SILABS C8051F MCU336-1452 - ADAPTER PROGRAM TOOLSTICK F340
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1299

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F341-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F341-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
C8051F340/1/2/3/4/5/6/7/8/9
19.3. Configuration and Operation
UART1 provides standard asynchronous, full duplex communication. It can operate in a point-to-point
serial communications application, or as a node on a multi-processor serial interface. To operate in a
point-to-point application, where there are only two devices on the serial bus, the MCE1 bit in SMOD1
should be cleared to ‘0’. For operation as part of a multi-processor communications bus, the MCE1 and
XBE1 bits should both be set to ‘1’. In both types of applications, data is transmitted from the microcon-
troller on the TX1 pin, and received on the RX1 pin. The TX1 and RX1 pins are configured using the cross-
bar and the Port I/O registers, as detailed in
In typical UART communications, The transmit (TX) output of one device is connected to the receive (RX)
input of the other device, either directly or through a bus transceiver, as shown in Figure 19.5.
19.3.1. Data Transmission
Data transmission is double-buffered, and begins when software writes a data byte to the SBUF1 register.
Writing to SBUF1 places data in the Transmit Holding Register, and the Transmit Holding Register Empty
flag (THRE1) will be cleared to ‘0’. If the UARTs shift register is empty (i.e. no transmission is in progress)
the data will be placed in the shift register, and the THRE1 bit will be set to ‘1’. If a transmission is in prog-
ress, the data will remain in the Transmit Holding Register until the current transmission is complete. The
TI1 Transmit Interrupt Flag (SCON1.1) will be set at the end of any transmission (the beginning of the
stop-bit time). If enabled, an interrupt will occur when TI1 is set.
If the extra bit function is enabled (XBE1 = ‘1’) and the parity function is disabled (PE1 = ‘0’), the value of
the TBX1 (SCON1.3) bit will be sent in the extra bit position. When the parity function is enabled (PE1 =
‘1’), hardware will generate the parity bit according to the selected parity type (selected with S1PT[1:0]),
and append it to the data field. Note: when parity is enabled, the extra bit function is not available.
19.3.2. Data Reception
Data reception can begin any time after the REN1 Receive Enable bit (SCON1.4) is set to logic 1. After the
stop bit is received, the data byte will be stored in the receive FIFO if the following conditions are met: the
receive FIFO (3 bytes deep) must not be full, and the stop bit(s) must be logic 1. In the event that the
receive FIFO is full, the incoming byte will be lost, and a Receive FIFO Overrun Error will be generated
(OVR1 in register SCON1 will be set to logic 1). If the stop bit(s) were logic 0, the incoming data will not be
stored in the receive FIFO. If the reception conditions are met, the data is stored in the receive FIFO, and
the RI1 flag will be set. Note: when MCE1 = ‘1’, RI1 will only be set if the extra bit was equal to ‘1’. Data can
be read from the receive FIFO by reading the SBUF1 register. The SBUF1 register represents the oldest
234
Figure 19.5. Typical UART Interconnect Diagram
COM Port
PC
RS-232
MCU
Section “15. Port Input/Output” on page 157
RX
Rev. 1.1
TX
TRANSLATOR
RS-232
LEVEL
OR
TX
RX
RX
TX
C8051Fxxx
C8051Fxxx
.

Related parts for C8051F341-GQ