ATXMEGA16A4-CU Atmel, ATXMEGA16A4-CU Datasheet - Page 83

MCU AVR 16+4KB FLASH 49VFBGA

ATXMEGA16A4-CU

Manufacturer Part Number
ATXMEGA16A4-CU
Description
MCU AVR 16+4KB FLASH 49VFBGA
Manufacturer
Atmel
Series
AVR® XMEGAr
Datasheets

Specifications of ATXMEGA16A4-CU

Core Processor
AVR
Core Size
8/16-Bit
Speed
32MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
34
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 3.6 V
Data Converters
A/D 12x12b, D/A 2x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
49-VFBGA
Processor Series
ATXMEGA16x
Core
AVR8
Data Bus Width
8 bit, 16 bit
Data Ram Size
2 KB
Interface Type
I2C/SPI/USART
Maximum Clock Frequency
32 MHz
Number Of Programmable I/os
34
Number Of Timers
5
Operating Supply Voltage
1.6 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR, EWAVR-BL
Development Tools By Supplier
ATAVRDRAGON, ATAVRISP2, ATAVRONEKIT
Minimum Operating Temperature
- 40 C
On-chip Adc
12-ch x 12-bit
On-chip Dac
2-ch x 12-bit
For Use With
ATAVRONEKIT - KIT AVR/AVR32 DEBUGGER/PROGRMMRATSTK600 - DEV KIT FOR AVR/AVR32770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAG770-1004 - ISP 4PORT FOR ATMEL AVR MCU SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATXMEGA16A4-CU
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
ATXMEGA16A4-CU
Quantity:
87
Part Number:
ATXMEGA16A4-CUR
Manufacturer:
Atmel
Quantity:
10 000
8077H–AVR–12/09
clock or oscillator is used to derive the System Clock (i.e clock reference for the PLL when this is
used as the active system clock) and an clock or oscillator fails (stops), the device will:
If the external oscillator fails when it is not used as the System Clock source, the external oscil-
lator is automatically disabled while the system clock will continue to operate normally.
If the external clock is below 32 kHz then the failure monitor mechanism should not be enabled
in order to avoid unintentional fail detection.
When the failure monitor is enabled, it cannot be disabled until next reset.
The failure monitor is automatically disabled in all sleep modes where the external clock or oscil-
lator is stopped. During wake-up from sleep it is automatically enabled again.
The External Clock Source Failure Monitor setting is protected by the Configuration Change Pro-
tection mechanism, employing a timed write procedure for changing the system clock and
prescaler settings. For details refer to
• Switch to the 2 MHz internal oscillator, independently of any clock system lock setting.
• Reset the Oscillator Control Register and System Clock Selection Register to their default
• Set the External Clock Source Failure Detection Interrupt Flag.
• Issue a non-maskable interrupt (NMI).
values.