ATXMEGA128D3-AU Atmel, ATXMEGA128D3-AU Datasheet - Page 38

MCU AVR 128K FLASH 3.6V 64TQFP

ATXMEGA128D3-AU

Manufacturer Part Number
ATXMEGA128D3-AU
Description
MCU AVR 128K FLASH 3.6V 64TQFP
Manufacturer
Atmel
Series
AVR® XMEGAr
Datasheet

Specifications of ATXMEGA128D3-AU

Core Processor
AVR
Core Size
8/16-Bit
Speed
32MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
50
Program Memory Size
128KB (64K x 16)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 3.6 V
Data Converters
A/D 16x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TQFP, 64-VQFP
Processor Series
XMEGA
Core
AVR
Data Bus Width
8 bit, 16 bit
Data Ram Size
8 KB
Interface Type
SPI, TWI, USART
Maximum Clock Frequency
32 MHz
Number Of Programmable I/os
50
Number Of Timers
5
Operating Supply Voltage
2.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR, EWAVR-BL
Minimum Operating Temperature
- 40 C
Operating Temperature Range
- 40 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATXMEGA128D3-AU
Manufacturer:
SIMCOM
Quantity:
1 000
Part Number:
ATXMEGA128D3-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATXMEGA128D3-AUR
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
ATXMEGA128D3-AUR
Quantity:
129
22. IRCOM - IR Communication Module
22.1
22.2
8134I–AVR–12/10
Features
Overview
XMEGA contains an Infrared Communication Module (IRCOM) for IrDA communication with
baud rates up to 115.2 kbps. This supports three modulation schemes: 3/16 of baud rate period,
fixed programmable pulse time based on the Peripheral Clock speed, or pulse modulation dis-
abled. There is one IRCOM available which can be connected to any USART to enable infrared
pulse coding/decoding for that USART.
Pulse modulation/demodulation for infrared communication
Compatible to IrDA 1.4 physical for baud rates up to 115.2 kbps
Selectable pulse modulation scheme
Built in filtering
Can be connected to and used by one USART at the time
– 3/16 of baud rate period
– Fixed pulse period, 8-bit programmable
– Pulse modulation disabled
XMEGA D3
38