ATXMEGA128D3-AU Atmel, ATXMEGA128D3-AU Datasheet - Page 89

MCU AVR 128K FLASH 3.6V 64TQFP

ATXMEGA128D3-AU

Manufacturer Part Number
ATXMEGA128D3-AU
Description
MCU AVR 128K FLASH 3.6V 64TQFP
Manufacturer
Atmel
Series
AVR® XMEGAr
Datasheet

Specifications of ATXMEGA128D3-AU

Core Processor
AVR
Core Size
8/16-Bit
Speed
32MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
50
Program Memory Size
128KB (64K x 16)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 3.6 V
Data Converters
A/D 16x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TQFP, 64-VQFP
Processor Series
XMEGA
Core
AVR
Data Bus Width
8 bit, 16 bit
Data Ram Size
8 KB
Interface Type
SPI, TWI, USART
Maximum Clock Frequency
32 MHz
Number Of Programmable I/os
50
Number Of Timers
5
Operating Supply Voltage
2.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR, EWAVR-BL
Minimum Operating Temperature
- 40 C
Operating Temperature Range
- 40 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATXMEGA128D3-AU
Manufacturer:
SIMCOM
Quantity:
1 000
Part Number:
ATXMEGA128D3-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATXMEGA128D3-AUR
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
ATXMEGA128D3-AUR
Quantity:
129
8134I–AVR–12/10
Figure 33-1. Analog Comparator Voltage Scaler vs. Scalefac
3. ADC gain stage cannot be used for single conversion
4.
5. ADC gain stage output range is limited to 2.4 V
Problem fix/Workaround
Use external voltage input for the analog comparator if accurate voltage levels are needed
The ADC gain stage will not output correct result for single conversion that is triggered and
started from software or event system.
Problem fix/Workaround
When the gain stage is used, the ADC must be set in free running mode for correct results.
ADC has increased INL error for some operating conditions
Some ADC configurations or operating condition will result in increased INL error.
In signed mode INL is increased to:
– 6LSB for sample rates above 130ksps, and up to 8LSB for 200ksps sample rate.
– 6LSB for reference voltage below 1.1V when VCC is above 3.0V.
– 20LSB for ambient temperature below 0 degree C and reference voltage below 1.3V.
In unsigned mode, the INL error cannot be guaranteed, and this mode should not be used.
Problem fix/Workaround
None, avoid using the ADC in the above configurations in order to prevent increased INL
error. Use the ADC in signed mode also for single ended measurements.
The amplified output of the ADC gain stage will never go above 2.4 V, hence the differential
input will only give correct output when below 2.4 V/gain. For the available gain settings, this
gives a differential input range of:
3.5
2.5
1.5
0.5
3
2
1
0
0
T = 25°C
5
10
15
20
25
SCALEFAC
30
35
40
45
50
55
XMEGA D3
60
65
3.3 V
2.7 V
1.8 V
89

Related parts for ATXMEGA128D3-AU