AT91SAM7X512-AU Atmel, AT91SAM7X512-AU Datasheet - Page 26

MCU ARM 512K HS FLASH 100-LQFP

AT91SAM7X512-AU

Manufacturer Part Number
AT91SAM7X512-AU
Description
MCU ARM 512K HS FLASH 100-LQFP
Manufacturer
Atmel
Series
AT91SAMr
Datasheet

Specifications of AT91SAM7X512-AU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
CAN, Ethernet, I²C, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
62
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
128K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-LQFP
Processor Series
AT91SAMx
Core
ARM7TDMI
Data Bus Width
32 bit
Data Ram Size
128 KB
Interface Type
CAN, SPI, SSC, TWI, USART, USB
Maximum Clock Frequency
55 MHz
Number Of Programmable I/os
13
Number Of Timers
3
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
JTRACE-ARM-2M, KSK-AT91SAM7X-PL, MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
AT91SAM-ICE, AT91-ISP, AT91SAM7X-EK
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit
No. Of I/o's
62
Ram Memory Size
128KB
Cpu Speed
55MHz
No. Of Timers
3
No. Of Pwm Channels
4
Digital Ic Case Style
LQFP
Rohs Compliant
Yes
For Use With
AT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9AT91SAM7X-EK - KIT EVAL FOR AT91SAM7X256/128
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7X512-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X512-AU
Manufacturer:
ATMEL
Quantity:
717
Part Number:
AT91SAM7X512-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X512-AU-999
Manufacturer:
Atmel
Quantity:
10 000
9.1
9.1.1
26
Reset Controller
AT91SAM7X512/256/128 Preliminary
Brownout Detector and Power-on Reset
The AT91SAM7X512/256/128 embeds one brownout detection circuit and a power-on reset cell.
The power-on reset is supplied with and monitors VDDCORE.
Both signals are provided to the Flash to prevent any code corruption during power-up or power-
down sequences or if brownouts occur on the power supplies.
The power-on reset cell has a limited-accuracy threshold at around 1.5V. Its output remains low
during power-up until VDDCORE goes over this voltage level. This signal goes to the reset con-
troller and allows a full re-initialization of the device.
The brownout detector monitors the VDDCORE and VDDFLASH levels during operation by
comparing them to a fixed trigger level. It secures system operations in the most difficult environ-
ments and prevents code corruption in case of brownout on the VDDCORE or VDDFLASH.
When the brownout detector is enabled and VDDCORE decreases to a value below the trigger
level (Vbot18-, defined as Vbot18 - hyst/2), the brownout output is immediately activated.
When VDDCORE increases above the trigger level (Vbot18+, defined as Vbot18 + hyst/2), the
reset is released. The brownout detector only detects a drop if the voltage on VDDCORE stays
below the threshold voltage for longer than about 1µs.
The VDDCORE threshold voltage has a hysteresis of about 50 mV, to ensure spike free brown-
out detection. The typical value of the brownout detector threshold is 1.68V with an accuracy of
± 2% and is factory calibrated.
When the brownout detector is enabled and VDDFLASH decreases to a value below the trigger
level (Vbot33-, defined as Vbot33 - hyst/2), the brownout output is immediately activated.
When VDDFLASH increases above the trigger level (Vbot33+, defined as Vbot33 + hyst/2), the
reset is released. The brownout detector only detects a drop if the voltage on VDDCORE stays
below the threshold voltage for longer than about 1µs.
The VDDFLASH threshold voltage has a hysteresis of about 50 mV, to ensure spike free brown-
out detection. The typical value of the brownout detector threshold is 2.80V with an accuracy of
± 3.5% and is factory calibrated.
The brownout detector is low-power, as it consumes less than 28 µA static current. However, it
can be deactivated to save its static current. In this case, it consumes less than 1µA. The deac-
tivation is configured through the GPNVM bit 0 of the Flash.
• Based on one power-on reset cell and one brownout detector
• Status of the last reset, either Power-up Reset, Software Reset, User Reset, Watchdog
• Controls the internal resets and the NRST pin output
• Allows to shape a signal on the NRST line, guaranteeing that the length of the pulse meets
Reset, Brownout Reset
any requirement.