SD6XA-064G-000000 SanDisk, SD6XA-064G-000000 Datasheet - Page 34

SSD ULTRA320 SCSI 64GB

SD6XA-064G-000000

Manufacturer Part Number
SD6XA-064G-000000
Description
SSD ULTRA320 SCSI 64GB
Manufacturer
SanDisk
Series
Ultra320r
Datasheet

Specifications of SD6XA-064G-000000

Memory Size
64GB
Memory Type
FLASH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
FFD35-U3S-64-N-P68-P
FFD35-U3S-64-N-P68-P
When the Master Command specifies only 1 or 2 sub-commands, parameters for the remaining
sub-commands are reserved and should be set to 0 for compatibility with future versions.
For the default Sanitize procedure, all other bits in the Master Command and parameters 1-3 are
reserved and should be set to 0 for compatibility with future versions.
Bits 0-1, 2-3, and 4-5 of the Master Command contain the following sub-commands:
34
Execute the default Sanitize procedure.
Erase the media (Security Erase).
USA-AF AFSSI 5020
Erase the media and overwrite with random
data.
USA Navy NAVSO P-5239-26
Erase the media and overwrite with random
data, then erase again.
o
o
Value of 0: Erase and fill with given character. The character is provided in the
corresponding parameter.
Value of 1: Erase and fill with random data, several times. The number of erase/fill loops is
provided in the corresponding parameter. Zero number of loops means erase once and do not
fill. Only the 7 least significant bits in the parameter are used to specify the number of loops.
The most significant bit is reserved for future extensions.
Value of 2 or 3: These sub-commands are reserved for future extensions.
Parameter1 corresponds to the sub-command in bits 0-1.
Parameter2 corresponds to the sub-command in bits 2-3.
Parameter3 corresponds to the sub-command in bits 4-5.
The Partition Mask is either a bitmap of partitions to be sanitized or value 0. In bitmap
mode, least-significant bit 1 corresponds to partition 0. Value of zero is a special value; it
corresponds to sanitizing the whole media regardless of partition configuration.
For example:
o
o
o
o
o
Value of 10b: Execute 2 sub-commands, defined in bits 0-1 and 2-3
Value of 11b: Execute 3 sub-commands, defined in bits 0-1, 2-3, and 4-5
Value of 0xF (or 1111 binary) corresponds to sanitizing all 4 partitions
Value of 0x8 (or 1000 binary) corresponds to sanitizing partition number 3
Value of 0x1 (or 0001 binary) corresponds to sanitizing partition number 0
Value of 0x5 (or 0101 binary) corresponds to sanitizing partitions 0 and 2
Value of 0 (or 0000 binary) corresponds to sanitizing the whole media
Operation
Table 25: Sanitize Procedure Options
Product Specification and User Manual
Command
Master
0x00
0x41
0x41
0x85
Parameter1
0x00
0x00
0x01
0x01
SSD (Formerly FFD) Ultra320 SCSI 3.5"
Parameter2
0x00
0x00
0x00
0x00
43-PS-0305-00 Rev. 2.2
Parameter3
0x00
0x00
0x00
0x00

Related parts for SD6XA-064G-000000