GS-BT2416C1DBAT1 STMicroelectronics, GS-BT2416C1DBAT1 Datasheet - Page 20

BOARD DEMO CLASS 1 W/SERIAL PORT

GS-BT2416C1DBAT1

Manufacturer Part Number
GS-BT2416C1DBAT1
Description
BOARD DEMO CLASS 1 W/SERIAL PORT
Manufacturer
STMicroelectronics
Type
Bluetoothr
Datasheets

Specifications of GS-BT2416C1DBAT1

Contents
Board
Processor Series
STLC2500
Wireless Frequency
2.4 GHz to 2.5 GHz
Interface Type
RS-232, USB
For Use With/related Products
GS-BT2416C1.A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-5793
AT command
A.3
20/38
Moreover it is possible to store a startup commands sequence directly into flash memory.
The sequence can be long up to 512bytes. If a macro sequence is present, in startup phase,
some OK events are generated, one for every command of the sequence, before the
+READY event.
This behavior can be avoided setting a AT+ECHO = OFF command starting the macro
(avoiding the +READY too). The sequence execution is stoppable changing the state of
GPIO3 in startup phase.
Interfaces
The module must be controlled by an external MCU using the UART and 2 GPIOs.
When these settings are changed by the AT+UARTSETUP command, they are stored in the
flash memory to be reloaded when the module is powered up the next time.
If GPIO3 is set to low, the module switches its mode of operation to COMMAND MODE.
UART: used to control the module with AT commands (COMMAND MODE), or
send/receive serial data to be transmitted over the SPP Bluetooth
The first time that the module is powered up, the default UART settings are as following
(saved in flash memory):
GPIO1: configured as output. GPIO1 is high when an SPP Bluetooth
device is present. GPIO1 is low when no Bluetooth
GPIO3: configured as input. If GPIO3 is set to high the module switches its mode of
operation to DATA MODE.
Baud rate: (bps) 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
®
link is present.
®
GS-BT2416C1.AT1
link (DATA MODE).
®
link to a remote