EM260-USART-JMP-R Ember, EM260-USART-JMP-R Datasheet - Page 39

KIT JUMP START FOR EM260

EM260-USART-JMP-R

Manufacturer Part Number
EM260-USART-JMP-R
Description
KIT JUMP START FOR EM260
Manufacturer
Ember
Series
JumpStartr
Type
802.15.4/Zigbeer

Specifications of EM260-USART-JMP-R

Frequency
2.4GHz
For Use With/related Products
EM260
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
636-1004
EM260-JMP
Bit
7 (MSB)
6
5
4
3
2
1
0 (LSB)
sleepMode[1]
1
1
0
0
overflow
1
0
truncated
1
0
Section 6.3.1 defines all the types used by the EM260 and section 6.3.2 defines all the structures. Section
6.3.3 enumerates all the named values for the different types. The subsequent sections list all the frames
supported by the EM260, specifying the Frame ID, the command parameters and the response parameters. The
list is divided into five sections:
Finally, section 6.3.9 provides an alphabetical list of all the frames.
Section 6.3.4 lists Configuration frames.
Section 6.3.5 lists Utilities frames.
Section 6.3.6 lists Networking frames.
Section 6.3.7 lists Binding frames.
Section 6.3.8 lists Messaging frames.
Command
0
0 (reserved)
0 (reserved)
0 (reserved)
0 (reserved)
0 (reserved)
sleepMode[1]
sleepMode[0]
sleepMode[0]
1
0
1
0
Description
The EM260 ran out of memory since the previous response.
No memory shortage since the previous response.
Description
The EM260 truncated the current response to avoid exceeding the maximum EZSP
frame length.
The current response was not truncated.
Table 19. Frame Control Byte
Table 22. Truncated Status
Table 21. Overflow Status
Table 20. Sleep Modes
Response
1
0 (reserved)
0 (reserved)
0 (reserved)
0 (reserved)
0 (reserved)
truncated
overflow
Description
Reserved.
Power down.
Deep sleep.
Idle.
120-1003-000D