IS-CL01-F-E NKK Switches, IS-CL01-F-E Datasheet - Page 18

SMARTSWITCH CONTROLLER OLED

IS-CL01-F-E

Manufacturer Part Number
IS-CL01-F-E
Description
SMARTSWITCH CONTROLLER OLED
Manufacturer
NKK Switches
Datasheet

Specifications of IS-CL01-F-E

Accessory Type
Controller
Description/function
SMARTSWITCH Development Kit
For Use With/related Products
OLED SmartSwitch™
For Use With
360-2344 - SWITCH OLED 64RGB X 48
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
360-2424
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
Commands to download information directly to OLED modules
Note: Care must be taken using these commands. The OLED modules could get damaged if they are
initialized with a value exceeding the specifications. Please check the OLED modules data sheet and
application notes before using commands.
Command to download data directly to OLED modules
[number] is one byte sent in ASCII HEX format (01H to 80H). This is the number of data bytes (1 to 128
bytes).
[data] is 1 to 128 bytes sent in ASCII HEX format.
The controller sends the [data] to both OLED modules as data.
Command to download a command directly to OLED modules
[number] is one byte sent in ASCII HEX format (01H to 80H). This is the number of data bytes (1 to 128
bytes).
[data] is 1 to 128 bytes sent in ASCII HEX format.
The controller sends the [data] to both OLED modules as a command.
Command to download a command directly to OLED modules (special)
[number] is one byte sent in ASCII HEX format (01H to 80H). This is the number of data bytes (1 to 128
bytes).
[data] is 1 to 128 bytes sent in ASCII HEX format.
The controller turns off the OLED display switches, sends the [data] to both switches as a command and then
turns on the OLED display switches.
CL01 Intelligent Controller Users Manual B.doc
This command downloads data directly from the host to the OLED module.
This command downloads a command from the host to the OLED module.
This command turns off the OLED module, downloads a command from the host to the OLED module,
and turns it back on.
command format: 2FH
transmit format:
command format: 2FH
transmit format:
command format: 2FH
transmit format:
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
CL01 Intelligent Controller Users Manual
(xxH) (xxH) (xxAH)
(xxH) (xxH) (xxAH)
(xxH) (xxH) (xxAH)
www.nkkswitches.com • Email engineering@nkkswitches.com
53H
47H
49H
[number]
[number]
[number]
(xxAH)
(xxAH)
(xxAH)
[data]
[data]
[data]
Page 18 of 24