PCF8534AU/DA/1,026 NXP Semiconductors, PCF8534AU/DA/1,026 Datasheet - Page 24

no-image

PCF8534AU/DA/1,026

Manufacturer Part Number
PCF8534AU/DA/1,026
Description
IC LCD DISPLAY DVR 60SEG
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCF8534AU/DA/1,026

Package / Case
Die
Display Type
LCD
Configuration
60 Segment
Interface
I²C
Current - Supply
8µA
Voltage - Supply
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Number Of Digits
30
Number Of Segments
240
Maximum Clock Frequency
400 KHz
Operating Supply Voltage
1.8 V to 5.5 V
Maximum Power Dissipation
400 mW
Maximum Operating Temperature
+ 85 C
Maximum Supply Current
50 mA
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Digits Or Characters
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
935287664026
NXP Semiconductors
PCF8534A_5
Product data sheet
8.2 I
Two I
The least significant bit of the slave address is bit R/W. The PCF8534A is a write-only
device. It will not respond to a read access, so this bit should always be logic 0. The
second bit of the slave address is defined by the level tied at input SA0. Two displays
controlled by PCF8534A can be recognized on the same I
The I
condition (S) from the I
slave addresses. All PCF8534As with the same SA0 level acknowledge in parallel to the
slave address. All PCF8534As with the alternative SA0 level ignore the whole I
transfer.
After acknowledgement, the control byte is sent defining if the next byte is RAM or
command information. The control byte also defines if the next byte is a control byte or
further RAM/command data (see
configure the device and then fill the display RAM with little overhead.
Table 8.
The command bytes and control bytes are also acknowledged by all addressed
PCF8534As connected to the bus.
The display bytes are stored in the display RAM at the address specified by the data
pointer and the subaddress counter. Both data pointer and subaddress counter are
automatically updated.
The acknowledgement after each byte is made only by the (A0, A1 and A2) addressed
PCF8534A. After the last display byte, the I
Alternatively a START may be issued to RESTART I
Bit
7
6
5 to 0
2
Fig 17. Control byte format
C-bus protocol
Up to 16 PCF8534As on the same I
The use of two types of LCD multiplex on the same I
2
2
C-bus protocol is shown in
C-bus slave addresses (0111 000 and 0111 001) are reserved for the PCF8534A.
Symbol
CO
RS
-
Load data pointer command bit description
Value
0
1
0
1
2
Rev. 05 — 6 August 2009
C-bus master which is followed by one of the available PCF8534A
MSB
CO
7
Figure
Figure 17
Description
continue bit
register selection
not relevant
RS
6
last control byte
control bytes continue
command register
data register
5
2
18. The sequence is initiated with a START
C-bus for very large LCD applications
Universal LCD driver for low multiplex rates
4
2
and
C-bus master issues a STOP condition (P).
not relevant
3
Table
2
2
C-bus access.
1
8). In this way it is possible to
mgl753
2
C-bus
0
2
LSB
C-bus which allows:
PCF8534A
© NXP B.V. 2009. All rights reserved.
2
C-bus
24 of 47

Related parts for PCF8534AU/DA/1,026