EVL90WADP-LLCSR STMicroelectronics, EVL90WADP-LLCSR Datasheet - Page 26

EVAL BOARD PORTABLE PWR SUPPLY

EVL90WADP-LLCSR

Manufacturer Part Number
EVL90WADP-LLCSR
Description
EVAL BOARD PORTABLE PWR SUPPLY
Manufacturer
STMicroelectronics
Type
Power Factor Correctionr

Specifications of EVL90WADP-LLCSR

Main Purpose
AC/DC, Primary and Secondary Side with PFC
Outputs And Type
1, Isolated
Power - Output
90W
Voltage - Output
19V
Current - Output
4.75A
Voltage - Input
90 ~ 264VAC
Regulator Topology
Boost
Frequency - Switching
130kHz
Board Type
Fully Populated
Utilized Ic / Part
L6563H, L6599A, SRK2000
Input Voltage
90 V to 264 V
Output Voltage
19 V
Dimensions
65 mm x 155 mm
Product
Power Management Modules
Supply Current
4.75 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
L6563H, L6599A, SRK2000
Other names
497-10377
Application information
26/36
The circuit shown in
series to C
operates like a capacitive current divider; C
less and will be a low-loss type, the sense resistor R
Equation 7
and C
If the resistor R
kΩ), the circuit operates like a divider of the ripple voltage across the resonant capacitor Cr,
which, in turn, is related to its current through the reactance of Cr. Again, C
selected equal to Cr/100 or less, this time not necessarily a low-loss type, while R
(provided it is << R
Equation 8
where the reactance of C
I
Whichever circuit one is going to use, the calculated values of Rs or R
considered just a first cut value that needs to be adjusted after experimental verification.
OCP is effective in limiting primary-to-secondary energy flow in case of an overload or an
output short circuit, but the output current through the secondary winding and rectifiers
under these conditions might be so high to endanger converter’s safety if continuously
flowing. To prevent any damage during these conditions it is customary to force converter’s
intermittent operation, in order to bring the average output current to values such that the
thermal stress for the transformer and the rectifiers can be easily handled.
With the L6599A the designer can program externally the maximum time T
converter is allowed to run overloaded or under short circuit conditions. Overloads or short
circuits lasting less than T
with immunity to short duration phenomena. If, instead, T
protection (OLP) procedure is activated that shuts down the L6599A and, in case of
continuous overload/short circuit, results in continuous intermittent operation with a user-
defined duty cycle.
Crpk
= I
B
Crpkx
will be such that R
A
. Again, C
is small (not above some hundred Ω, just to limit current spiking) the circuit
A
in series to C
A
) according to:
Figure 28
B
will be such that R
A
SH
B
(X
·C
will not cause any other action, hence providing the system
CA
B
A
b can be operated in two different ways. If the resistor R
Doc ID 15308 Rev 5
is in the range of 10 /f
is not small (in this case it will be typically selected in the ten
) and Cr (X
R
R
B
B
=
=
I
0
Crpkx
I
8 .
0
Crpkx
B
8 .
Cr
A
π
·C
) should be calculated at the frequency where
will be typically selected equal to Cr/100 or
π
B
⎜ ⎜
R
1
is in the range of 10 /f
2
A
+
X
+
C
Cr
C
B
X
A
r
min
will be selected as:
2
C
⎟ ⎟
A
.
SH
is exceeded an overload
min
B
should be
.
A
SH
will be typically
that the
B
L6599A
A
in

Related parts for EVL90WADP-LLCSR