C500TS502 Omron, C500TS502 Datasheet - Page 36

no-image

C500TS502

Manufacturer Part Number
C500TS502
Description
RTD INPUT MODULE
Manufacturer
Omron
Datasheet

Specifications of C500TS502

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
30
Module Memory Map
Read/
write
R
R
R
R
R
R
R
R
R
R
R/W
R/W
Memory
map word
11
12
13
14
15
16
17
18
19
19
20
20
21
21
22
22
23
24
25
Bits
0 to 7
8 to 15
0 to 7
8 to 15
0 to 7
8 to 15
0 to 7
8 to 15
0 to 7
0 to 7
1
2
3
4
5
6
7
8
1 thru 8
1 thru 8
1 thru 8
1 thru 8
1 thru 8
1 thru 8
1 thru 8
1 thru 8
1 thru 8
1 thru 8
Input
point
Function
Peak hold data
Input point active flags
Peak hold active flags
BCD/binary select flags
Scaling active flags
Averaging active flags
Filtering active flags
Low alarm active flags
High alarm active flags
°C/°F select flags
Pointer word
Input point enable bits
Description
These words contain the latest peak
hold values for each input point. The
data format Is determined by word
26, bits and 0 to 7. The module
performs scaling and filtering
functions if selected before placing
peak hold values in these words. The
peak hold function is enabled/
disabled for each input point by
setting bits in word 25, bits 8 to 15.
These words are reset by I/O word n,
bits 8 thru 15. The module
acknowledges the reset in I/O word
n+1 bits 8 to15. See Section 4--3--5
for operation details of the peak hold
function.
These flags are set by the module
indicating the enable/disable status of
each input point that is set in word
25, bits 0 to 7.
These flags are set by the module
indicating the enable/disable status of
the peak hold function for each input
point set in word 25, bits 8 to 15.
These flags are set by the module
indicating the data format selected for
each input point in word 26, bits
0 to 7.
These flags are set by the module
indicating the enable/disable status of
the scaling function for each input
point set in word 26, bits 8 to 15.
These flags are set by the module
indicating the enable/disable status of
the averaging function for each input
point set in word 27, bits 0 to 7.
These flags are set by the module
indicating the enable/disable status of
the filtering function for each input
point set in word 27, bits 8 to 15.
These flags are set by the module
indicating the enable/disable status of
the low alarm function for each input
point set in word 28, bits 0 to 7.
These flags are set by the module
indicating the enable/disable status of
the high alarm function for each input
point set in word 28, bits 8 to 15.
These flags are set by the module
indicating the scale format selected
for each input point in word 29, bits 0
to 7.
The pointer word is used to set the
starting location in the module
memory map for the I/O read and I/O
write instructions that are executed in
ladder logic in the PLC. This allows
the user to selectively read and write
parts of the module memory map.
These bits are set by the user to
enable/disable each input point. The
module scans only input points that
are enabled. The default value is all
input points enabled.
Section 5-1

Related parts for C500TS502