NL10276BC16-01 NEC, NL10276BC16-01 Datasheet - Page 9

TFT DISPLAY, 8.4"

NL10276BC16-01

Manufacturer Part Number
NL10276BC16-01
Description
TFT DISPLAY, 8.4"
Manufacturer
NEC
Datasheet

Specifications of NL10276BC16-01

Lcd Display Type
XGA
Display Mode
Active
Interface Type
LVDS
Viewing Area (h X W)
127.872mm X 170.496mm
Supply Voltage
3.3V
Operating Temperature Range
0°C To +55°C
Pixel Size (h X W)
0.166mm X 0.166mm
Backlight Type
CCFL
Display Technology
LCD
Luminance
400cd/m2
Rohs Compliant
Yes
Pixel Pitch (h X W)
0.1665mm X 0.1665mm
Svhc
No SVHC (20-Jun-2011)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NL10276BC16-01
Manufacturer:
NEC
Quantity:
1
Part Number:
NL10276BC16-01
Manufacturer:
NEC
Quantity:
1 000
4.3.2 Backlight lamp
Note1: This product consists of 4 backlight lamps, and these specifications are for each lamp.
Note2: The lamp voltage cycle between lamps should be kept on a same phase. "VS" and "VBLH"
Note3: The asymmetric ratio of working waveform for lamps (Power supply voltage peak ratio,
Note4: This product's backlight consists of 2 lamp holders, and each lamp holder contains 2 lamps. 2
Note5: The inverter should be designed so that the lamp starting voltage can be maintained for more
Note6: In case "FO" is not the recommended value, beat noise may display on the screen, because of
Lamp current
Lamp voltage
Lamp starting voltage
Lamp oscillation frequency
are the voltage value between low voltage side (Cold) and high voltage side (Hot).
power supply current peak ratio and waveform space ratio) should be less than 5 % (See the
following figure.). If the waveform is asymmetric, DC (Direct current) element apply into the
lamp. In this case, a lamp lifetime may be shortened, because a distribution of a lamp
enclosure substance inclines toward one side between low voltage terminal (Cold terminal)
and high voltage terminal (Hot terminal). When designing the inverter, evaluate asymmetric of
lamp working waveform sufficiently.
lamps are contained in the 1 lamp holder, and both lamps are connected to 1 low voltage cable.
Lamp current must be 5.0mArms typical for each lamp, and sum of 2 lamps must be
10mArms typical. (with whole product: 20.0mArms) The lamp current should be measured by
high-frequency current meter at the low voltage terminal.
than 1 second. Otherwise the lamp may not be turned on.
interference between "FO" and "1/th". Recommended value of "FO" is as following.
Pa: Supply voltage/current peak for positive, Pb: Supply voltage/current peak for negative
Sa: Waveform space for positive part, Sb: Waveform space for negative part.
th: Horizontal cycle (See "4.9.2 Timing characteristics".)
n : Natural number (1, 2, 3 ⋅⋅⋅⋅⋅⋅⋅⋅)
Pb
Pa
Parameter
0
FO =
Sa
1
4
×
DATA SHEET DOD-PP-0232 (5th edition)
th
1
Symbol
VBLH
IBL
× (2n-1)
VS
FO
Sb
1,140
min.
875
3.0
49
-
typ.
440
5.0
54
-
-
|Pa - Pb|
|Sa - Sb|
Pb
Sb
max.
5.5
59
-
-
-
× 100 ≤ 5 %
× 100 ≤ 5 %
mArms
Vrms
Vrms
Vrms
Unit
kHz
NL10276BC16-01
(Ta = 25°C, Note1)
at IBL=5.0mArms:
Note2, Note3,
Note2, Note3,
Note3, Note4
Note2, Note3
Note5, Note8
Note5, Note8
Ta = 25°C
400cd/m
Remarks
Ta = 0°C
Note6
2
9

Related parts for NL10276BC16-01