ADNK-6710 Avago Technologies US Inc., ADNK-6710 Datasheet - Page 7

Automatic Laser Calibration Tool

ADNK-6710

Manufacturer Part Number
ADNK-6710
Description
Automatic Laser Calibration Tool
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ADNK-6710

Tool Type
Laser Power Calibrator
Description/function
Optical Mouse Sensor Kit
Interface Type
USB
Product
Display Modules
Touch Panel
No Touch Panel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
Laser Power Alignment
Lead Free Status / Rohs Status
No
Read from EEPROM
Test Mouse LOP
Echo Device

From Host to device
[Command Code][Register Address][Dummy Value]
Where
[Command Code] is a hexadecimal command code with value = 0x21
[Register Address] is the EEPROM address to read from, value from 0 to FF, 256 bytes only
[Dummy Value] is a dummy hex value, e.g 0x00
Eg. EEPROM Read value from EEPROM address 0x0FF
0x210xFF0x00
Reply from Device to Host
0x210x010xVV if read from the EEPROM success
where 0xVV is the value read
0x210x000xYY if read from the EEPROM fail
where 0xYY is a dummy hex value, e.g 0x00
From Host to device
[Command Code][Dummy Value][Dummy Value]
where
[Command Value] is a hexadecimal command code,
if 0x50 = Enabled test mouse LOP;
if 0x51 = Disabled test mouse LOP
and [Dummy Value] = Dummy hex value, e.g 0x00
Eg. Request Mouse to perform self LOP test
0x500x000xYY
Reply from Device to Host
0x500x010x00 if enable Test Mouse LOP success
0x500x000x00 if enable Test Mouse LOP fail
0x510x010x00 if disable Test Mouse LOP success
0x510x000x00 if disable Test Mouse LOP fail
From Host to device
[Command Code][Dummy Value][Dummy Value]
where
[Command Code] is a hexadecimal command code with value = 0x60
[Dummy Value] = Any dummy hex value, e.g 0x88
Eg. Request Mouse to perform echo test
0x600x880x99
Reply from Device to Host
0x600x088x99 if echo success
0x600x000x00 if echo fail