EM1-H0R0V-1N SENSIRION, EM1-H0R0V-1N Datasheet
EM1-H0R0V-1N
Specifications of EM1-H0R0V-1N
Related parts for EM1-H0R0V-1N
EM1-H0R0V-1N Summary of contents
Page 1
... The CMOSens supply voltage of 7…18 Vdc and provides an RS232 and SPI compliant electrical interface. EM1 is RoHS compliant. ® EM1 Mass Flow Meter. ® EM1 Mass Flow Meter is suitable for a wide ® EM1 Mass Flow Meter requires a Sensirion - the sensor company ...
Page 2
... EM1 Mass Flow Meter to a PC. The serial peripheral interface (SPI) also enables the ® CMOSens EM1 Mass Flow Meter to be used in smaller micro controller systems special interface such current output or other or another flow range is required, contact Sensirion for a customer specific solution. ...
Page 3
... CMOSens EM1 Mass Flow Meter Performance Table 1: Specifications of EM1 Mass Flow Meter – low flow ranges. All data unless otherwise noted apply for calibration conditions: 20°C, N2, 1013 mbar absolute pressure, horizontal mounting position, straight inlet fitting (length min ∅) Specification ...
Page 4
... CMOSens EM1 Mass Flow Meter for Gases Table 2: Specifications of EM1 Mass Flow Meter – medium and high flow ranges. All data unless otherwise noted apply for calibration conditions: 20°C, N2, 1013 mbar absolute pressure, horizontal mounting position, straight inlet fitting (length min ∅) ...
Page 5
... CMOSens EM1 Mass Flow Meter for Gases ® Table 4: CMOSens EM1 Mass Flow Meter Resolution (EM1_V) at different Flow Levels and integration time. Flow Level Flow Level 200 ln/min 50 ln/min < 5 ln/min Mass Flow Integration Time 1.1 Gas Flow Characteristics Figure 2 shows the applied gas flow vs. the digital ® ...
Page 6
... Any leakage even outside the controller can be dangerous. The CMOSens according to EN 50020 chapter 6.2.4 b) for the safe use of gases of class T4 or group 1 (as mixtures of air with hydrogen or hydrocarbons). Data Sheet EM1 - v 2.6 / October 2006 ® EM1 Mass Flow Meter. Wetted Material Polycarbonate ...
Page 7
... Temp. scale factor EM1NH 1/100 EM1NL 1/50 EM1NR 1 EM1NV 1/128 www.sensirion.com Example for EM1NV: a received value of +1234 (dec) corresponds either to 9.641 ln/min in flow mode or 12.34 °C in temperature mode. An explanation of the overflow modes can be found in section 1.1. received value (hex) 0x7852 0x7851 0x7850 0x0001 ...
Page 8
... Mass Flow Meter is not selected. ® EM1 devices MISO (Master In Slave Out, Not Connected) The CMOSens supports a uni-directional SPI protocol. Therefore, the MISO pin should always left unconnected. Data Sheet EM1 - v 2.6 / October 2006 + 560 MICRO- 560 CONTROLLER 560 ...
Page 9
... The commands are not case sensitive. • In order to send a new command to the EM1 Mass Flow Meter make sure the EM1 is not in measurement mode. Issue therefore a stop command s first. After this, any instruction can be given to the EM1 Mass Flow Meter and a new series of measurement can be started by go↵ ...
Page 10
... Data Sheet EM1 - v 2.6 / October 2006 mode and is pushing ...
Page 11
... Output Short Circuit Current RS232 Input Voltage Range Voltage Threshold Low High Hysteresis Resistance ® Table 11: CMOSens EM1 SPI Characteristics (refer to Figure 10 for a timing diagram). Symbol Parameter Vol Output Low Voltage Voh Output High Voltage Vol Output Low Voltage Voh Output High Voltage ...
Page 12
... Note: Free PC Software supporting serial RS232 communication can be downloaded from http://www.sensirion.com www.sensirion.com tst twait bit bit 14...9 8 ® MFM SPI Interface. ® EM1 device SPI mode data access protocol. Data Sheet EM1 - v 2.6 / October 2006 LSB bit bit bit 7 6... ...
Page 13
... CMOSens EM1 Mass Flow Meter for Gases 5 www.sensirion.com Data Sheet EM1 - v 2.6 / October 2006 ...
Page 14
... No. 3101 1417 ; G3/8; Tube OD=14mm Plastics: Hausamann (www.hausammann.com) No. 38.129; G3/8; Tube ID=6mm No. 38.130; G3/8; Tube ID=8mm No. 38.131; G3/8; Tube ID=10mm No. 38.132; G3/8; Tube ID=13mm Manifold version with 90° angle (for volume applications) ® EM1. All units are in [mm] Data Sheet EM1 - v 2.6 / October 2006 ...
Page 15
... EM1 Mass Flow Meter for Gases 6 Ordering Information ® When ordering CMOSens EM1 series devices please refer to the following part numbers. For the latest product information access Sensirion’s website on http://www.sensirion.com Table 12: Overview ordering information Calibrated for Gas Type Air ...
Page 16
... Copyright CMOSens All rights reserved. Data Sheet EM1 - v 2.6 / October 2006 such defects shall be found, to SENSIRION’s reasonable satisfaction, to have arisen from SENSIRION’s faulty design, material, or workmanship; the defective product shall be returned to SENSIRION’ ...
Page 17
... CMOSens EM1 Mass Flow Meter for Gases FCC and CE Statement The EM1 product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules (FCC CFR 47). These limits are designed to provide reasonable protection against harmful interference in a residential installation ...