L6470HTR STMicroelectronics, L6470HTR Datasheet - Page 55

IC STEPPER/DC MOTOR DVR 28HTSSOP

L6470HTR

Manufacturer Part Number
L6470HTR
Description
IC STEPPER/DC MOTOR DVR 28HTSSOP
Manufacturer
STMicroelectronics
Datasheets

Specifications of L6470HTR

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-10812-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6470HTR
Manufacturer:
ST
0
Part Number:
L6470HTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6470HTR
0
Company:
Part Number:
L6470HTR
Quantity:
9 000
L6470
9.2.5
Note:
9.2.6
Run (DIR, SPD)
Table 40.
The Run command produces a motion at SPD speed; the direction is selected by DIR bit: '1'
forward or '0' reverse. The SPD value is expressed in step/tick (format unsigned fixed point
0.28) that is the same format that SPEED register (see paragraph 9.1.4).
The SPD value should be lower than MAX_SPEED and greater than MIN_SPEED
otherwise the Run command will be executed at MAX_SPEED or MIN_SPEED respectively.
This command can be given anytime and is immediately executed.
StepClock (DIR)
Table 41.
The StepClock command switches the device in step clock mode (see paragraph
impose the forward (DIR = '1') or reverse (DIR = '0') direction.
When the device is in step clock mode the SCK_MOD flag in STATUS register is raised and
the motor is always considered stopped (see paragraphs
Device exits from step clock mode when a constant speed, absolute positioning or motion
command is sent through SPI. Motion direction is imposed by the respective StepClock
command argument and can by changed by a new StepClock command without exiting the
step clock mode.
Events that cause bridges to be forced in high impedance state (overtemperature,
overcurrent, etc.) do not cause the device to leave step clock mode.
This command can only be given when the motor is stopped. If a motion is in progress the
motor should be stopped and then it is possible to send a StepClock command.
Any attempt to perform a StepClock command when the motor is running causes the
command to be ignored and the NOTPERF_CMD flag to rise (see paragraph
Bit 7
Bit 7
X
0
0
Bit 6
Bit 6
X
Run command structure
1
Stepclock command structure
1
Bit 5
Bit 5
X
0
0
Bit 4
Bit 4
SPD (Byte 1)
SPD (Byte 0)
Doc ID 16737 Rev 2
X
1
1
Bit 3
Bit 3
0
1
Bit 2
Bit 2
SPD (Byte 2)
0
0
Bit 1
Bit 1
6.7.5
0
0
and
Bit 0
DIR
Bit 0
DIR
9.1.22
Programming manual
).
from host
from host
from host
from host
from host
9.1.22
6.7.5
).
) and
55/64

Related parts for L6470HTR