BK2534 B&K Precision, BK2534 Datasheet - Page 65

OSCOPE 60MHZ DIGITAL STORAGE

BK2534

Manufacturer Part Number
BK2534
Description
OSCOPE 60MHZ DIGITAL STORAGE
Manufacturer
B&K Precision
Type
Bench, Digitalr
Datasheets

Specifications of BK2534

Includes
Probes, Software, USB Cable
Bandwidth
60MHz
Channels
Dual
Display Type
LCD - Color
Features
Software Controllable, USB Port, Waveform Capture
Probe Type
PR-37A x1/x10/Ref Probes (2)
Sampling Rate (per Second)
400MSa/s
Input Impedance
1M - 19pF
Rise Time (typ)
5.83nS
Voltage - Input, Max
400Vpeak
Voltage - Supply
100 ~ 240VAC
Lead Free Status / RoHS Status
Not applicable / Not applicable
3. Application Examples
This section presents 7 typical application examples. These
examples highlight the features of the oscilloscope and give
you ideas on how to solve your own test problems.
Make Simple Measurements
You need to measure the amplitude and frequency of an
unknown signal on CH1.
Perform following steps to quickly display the signal.
The oscilloscope automatically sets the vertical, horizontal,
and trigger controls. You can adjust any of these controls
manually if you need to optimize the display of the waveform.
When you are using both CH1 and CH2 channels, the
Autoset function sets the vertical controls for each channel
and uses the CH1 channel to set the horizontal and trigger
controls.
The oscilloscope can automatically display most signals.
Perform following steps to measure signal amplitude and
frequency.
 
Connect the channel 1 probe to the unknown signal.
Press the AUTO key.
Application Examples
129
130
Application Examples
 
Press the MEASURE key to display the MEASURE
menu.
Press the Voltage softkey to display the VOLTAGE
menu.
Press the Amplitude softkey to measure the amplitude.
The amplitude value will be displayed at the bottom of
the screen.
Press the MEASURE key again to display the
MEASURE menu.
Press the Time softkey to display the TIME menu.
Press the Frequency softkey to measure the frequency.
The frequency value will be displayed at the bottom of
the screen to the right of the voltage value.