NT31C-ST143-EV3 Omron, NT31C-ST143-EV3 Datasheet - Page 219

no-image

NT31C-ST143-EV3

Manufacturer Part Number
NT31C-ST143-EV3
Description
5.7 8-Color Dsp,STN,Ivory,Eng
Manufacturer
Omron
Datasheet

Specifications of NT31C-ST143-EV3

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
System Maintenance
6-11-6 Checking Screen Data
* Default (factory) setting
202
Display of Lamp/
Touch SW No.
Display of Memory
Table No.
Display of image/
Library No.
Display of Broken
Line Frame
Setting Item
Reference:
Allows designation of whether the bit number of the lamp bit set for a lamp or touch
switch is displayed or not.
The display format is as follows L@❍❍❍❍❍❍❍ (@: area type, ❍❍❍❍❍❍❍: bit number).
Allows designation of whether the table numbers of numeral and character string mem-
ory tables are displayed or not.
The display format for numeral memory tables is N❍❍❍❍ and the display format for
character string memory tables is S❍❍❍❍.
This function is valid for the following display elements.
- Numeral displays
- Character string displays
- Bar graphs
- Numeral setting input fields (including thumbwheel type)
- Character string input fields
Allows designation of whether image/library code numbers are displayed or not.
Allows designation of whether or not broken line frames are displayed around the dis-
play elements for showing the positions registered.
Example Print-out
All of the recorded data is printed out in the same order as on the currently
displayed screen.
Example:
Sort by occurrence method, from oldest record
The NT31/NT31C allows the registered screens (Nos. 1 to 3999) to be dis-
played and checked by operation from the System Menu.
Specifying The Display Method
Specify the display method for the screens as indicated in the table below.
No. Comment
1
2
3
• Window screens cannot be displayed by operation from the System
• Only the user screens (Nos. 1 to 3999) can be displayed. Screens for sys-
Menu.
tem use cannot be displayed.
Remote I/O Error
PIC Unit Error
Cycle Time Over
Function
The NT31/NT31C returns to the ALARM
HISTORY MENU screen.
Press Quit.
YY/MM/DD HH:MM 01/01
98/02/06
98/02/07
98/02/17
16:02
09:21
15:44
Section 6-11
ON, OFF*
ON, OFF*
ON, OFF*
ON, OFF*
Options
Setting

Related parts for NT31C-ST143-EV3