DCN4-BR4D Omron, DCN4-BR4D Datasheet - Page 67

no-image

DCN4-BR4D

Manufacturer Part Number
DCN4-BR4D
Description
Thin Cable-Flat Cable Conv Con
Manufacturer
Omron
Datasheet

Specifications of DCN4-BR4D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Cables, Connectors, and Related Devices
Connecting
Communications
Cables
Communications
Cable Specifications
Special Thin/Thick Cable
46
Model
Conductor cross-sectional area 0.86 mm
Conductor outer diameter
Color
Impedance
Propagation delay
Attenuation factor
Conductor resistance
Maximum current
Finished outer diameter
Terminating
Resistor
(121 Ω )
Terminators are
required at both
ends of the network.
Item
CAN H (White)
CAN L (Blue)
V- (Black)
V+ (Red)
Shield
Power Supply Tap
Note The ground may introduce noise into the network if a poor quality ground is
Communications
Power Supply
(24 V DC)
Ground the network
at one point only.
DCA2-5C10
1.21 mm
Blue and white
120 Ω ±10%
1.36 ns/ft
500 kHz: 0.25 dB/
100 ft
125 kHz: 0.13 dB/
100 ft
6.9 Ω/1,000 ft
22.6 Ω/1,000 m
---
11.2 to 12.1 mm
used and the FG terminal is connected to the V- terminal. If a good ground of
100 Ω or less is not available, do not connect the communication power sup-
ply’s FG and V- terminals.
Conductor
3
4
Signal wires
No.
2
Ground
(100 Ω or less)
Trunk line
T-branch Tap
or T-branch
Connector
Thick Cable
Blue
Black
Insulation
color
2.17 mm
1.92 mm
Red and black
---
---
---
2.7 Ω/1,000 ft
8.9 Ω/1,000 m
8 A
T-branch Tap or
T-branch Connector
Power wires
CAN L
(signal low)
V−
(communica-
tions power sup-
ply negative side)
Node
Application
2
Connec-
tor
Branch line
DCA1-5C10
0.20 mm
Blue and white
1.36 ns/ft
100 ft
125 kHz: 0.29 dB/
100 ft
28 Ω/1,000 ft
91.9 Ω/1,000 m
---
6.9 mm
0.60 mm
120 Ω ±10%
500 kHz: 0.50 dB/
0.5 mm
(AWG21)
0.75mm
(AWG19)
Signal wires
Nominal
section
cross-
V+ (Red)
CAN H (White)
Shield
CAN L (Blue)
V- (Black)
2
2
2
Node
Thin Cable
37.5 max.
25.0 max.
Conductor
resistance
(Ω/km)
Terminating
Resistor
(121 Ω )
0.38 mm
0.80 mm
Red and black
---
---
---
17.5 Ω/1,000 ft
57.4 Ω/1,000 m
3 A
Terminators are
required at both
ends of the network.
Power wires
Section 2-3
2
current (A)
---
5 max.
Allowable

Related parts for DCN4-BR4D