DCN4-BR4D Omron, DCN4-BR4D Datasheet - Page 85

no-image

DCN4-BR4D

Manufacturer Part Number
DCN4-BR4D
Description
Thin Cable-Flat Cable Conv Con
Manufacturer
Omron
Datasheet

Specifications of DCN4-BR4D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Wiring Methods
64
7. Tighten the connector’s set screws on the wires using a slotted screwdriver
White (CAN H)
Blue (CAN L)
Insertion
direction
Note (a) Be sure that the wire set screws are sufficiently loosened before
that doesn’t taper at the tip, which will prevent the screwdriver from binding
in the connector. Tighten the screws to a torque of between 0.25 and
0.3 N ⋅ m
Black (V − )
tion direction are perpendicular. Use right-angle connectors if there is
insufficient wiring space in front of the DeviceNet connectors and the
connectors must be wired from the side.
Connectors without set screws do not require lines to be secured with
screws as with previous connectors. Push up the orange lever and
then insert each line into the back of each hole.
Release the orange lever after inserting the lines, and gently pull each
line to check that it is securely connected to the connector.
(b) There are colored stickers provided on the Master Unit and Slave
(c) The following table shows the cable colors:
Red (V+)
Black
Blue
---
White
Red
attempting to insert the lines. If these screws are not loose, the
wires will go into the space in the back of the connector and can-
not be locked with the set screws.
Units that match the colors of the lines to be inserted. Be sure that
the colors match when wiring the connectors.
Attachment
screw
Color
Wiring
direction
Communications power supply, negative V−
Signal line, Low
Shield
Signal line, High
Communications power supply, positive
Red (V+)
White (CAN H)
Shield
Black (V − )
Blue (CAN L)
Shield
Signal
CAN L
S
CAN H
V+
Section 2-4
Symbol

Related parts for DCN4-BR4D