Ethernet ICs Three Port 10/100 Ethernet Switch

LAN9313-NZW

Manufacturer Part Number
LAN9313-NZW
Description
Ethernet ICs Three Port 10/100 Ethernet Switch
Manufacturer
SMSC
Type
Three Port Managed Ethernet Switchr
Datasheet

Specifications of LAN9313-NZW

Ethernet Connection Type
10 Base-T, 100 Base-TX
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Product
Ethernet Switches
Number Of Transceivers
1
Standard Supported
802.3, 802.3u
Data Rate
10 Mbps, 100 Mbps
Supply Voltage (max)
3.6 V
Supply Voltage (min)
0 V
Supply Current (max)
155 mA, 270 mA
Maximum Operating Temperature
+ 70 C
Package / Case
TQFP-100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9313-NZW
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
LAN9313-NZW
Manufacturer:
SMSC
Quantity:
20 000
Revision 1.7 (06-29-10)
13.2.2.9
MODE[2:0]
BITS
15:8
7:5
4:0
000
001
010
RESERVED
PHY Mode (MODE[2:0])
This field controls the PHY mode of operation. Refer to
definition of each mode.
PHY Address (PHYADD)
The PHY Address field determines the MMI address to which the PHY will
respond and is also used for initialization of the cipher (scrambler) key. Each
PHY must have a unique address. Refer to
Addressing," on page 84
Note:
Port x PHY Special Modes Register (PHY_SPECIAL_MODES_x)
This read/write register is used to control the special modes of the Port x PHY.
Note: This register is re-written by the EEPROM Loader following the release of reset or a RELOAD
Note 13.60 Register bits designated as NASR are reset when the Port x PHY Reset is generated via
Note 13.61 The default value of this field is determined by a combination of the configuration straps
Note 13.62 The default value of this field is determined by the phy_addr_sel_strap configuration strap.
10BASE-T Half Duplex. Auto-negotiation disabled.
10BASE-T Full Duplex. Auto-negotiation disabled.
100BASE-TX Half Duplex. Auto-negotiation
disabled. CRS is active during Transmit & Receive.
No check is performed to ensure that this address is unique from
the other PHY addresses (Port 1 PHY, Port 2 PHY, and Virtual
PHY).
command. Refer to
Index (decimal): 18
the
t h e
(PHY_BASIC_CONTROL_x)
autoneg_strap_x, speed_strap_x, and duplex_strap_x. If the autoneg_strap_x is 1, then
the default MODE[2:0] value is 111b. Else, the default value of this field is determined by
the remaining straps. MODE[2]=0, MODE[1]=(speed_strap_1 for Port 1 PHY,
speed_strap_2 for Port 2 PHY), and MODE[0]=(duplex_strap_1 for Port 1 PHY,
duplex_strap_2 for Port 2 PHY). Configuration strap values are latched upon the de-
assertion of a chip-level reset as described in
page
definitions.
Refer to
Reset Control Register
MODE DEFINITIONS
R e s e t ( P H Y _ R S T )
45. Refer to
Section 7.1.1, "PHY Addressing," on page 84
for additional information.
Table 13.10 MODE[2:0] Definitions
DESCRIPTION
Section 8.2.4, "EEPROM Loader," on page 113
Section 4.2.4, "Configuration Straps," on page 45
DATASHEET
(RESET_CTL). The NASR designation is only applicable when
is set.
Section 7.1.1, "PHY
b i t o f t h e
246
Size:
Table 13.10
P o r t x P H Y B a s i c C o n t r o l R e g i s t e r
PHY_BASIC_CONTROL_x
AFFECTED REGISTER BIT VALUES
Section 4.2.4, "Configuration Straps," on
[13,12,10,8]
Three Port 10/100 Managed Ethernet Switch with MII
16 bits
0000
0001
1000
for a
for additional information.
Note 13.60
Note 13.60
for more information.
NASR
NASR
TYPE
R/W
R/W
SMSC LAN9313/LAN9313i
RO
for configuration strap
PHY_AN_ADV_x
[8,7,6,5]
DEFAULT
N/A
N/A
N/A
Note 13.61
Note 13.62
Datasheet
-

Related parts for LAN9313-NZW