SI3200-G-GS Silicon Laboratories Inc, SI3200-G-GS Datasheet - Page 65

no-image

SI3200-G-GS

Manufacturer Part Number
SI3200-G-GS
Description
SLIC 2-CH 63dB 45mA 3.3V 6-Pin SMD
Manufacturer
Silicon Laboratories Inc
Series
ProSLIC®r
Datasheets

Specifications of SI3200-G-GS

Package
6SMD
Number Of Channels Per Chip
2
Polarity Reversal
Yes
Longitudinal Balanced
63 dB
Loop Current
45 mA
Minimum Operating Supply Voltage
3.13 V
Typical Operating Supply Voltage
3.3 V
Typical Supply Current
0.11 mA
Function
Subscriber Line Interface Concept (SLIC), CODEC
Interface
GCI, PCM, SPI
Number Of Circuits
2
Voltage - Supply
3.3V, 5V
Current - Supply
110µA
Power (watts)
941mW
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-SOIC (3.9mm Width)
Includes
Battery Switching, BORSCHT Functions, DTMF Generation and Decoding, FSK Tone Generation, Modem and Fax Tone Detection
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3200-G-GS
Manufacturer:
SiliconL
Quantity:
48
Part Number:
SI3200-G-GS
Manufacturer:
Genesis
Quantity:
510
Part Number:
SI3200-G-GSR
Manufacturer:
SILICON
Quantity:
12 000
Part Number:
SI3200-G-GSR
Manufacturer:
SILICON/PBF
Quantity:
1 619
CALR2: Calibration 2 (Register Address 12)
(Register type: Initialization)
Reset settings = 0x3F
Name
Type
Bit
7:6
Bit
5
4
3
2
1
0
CALCMBAL
CALMADC
CALDACO
CALADCO
CALLKGR
CALLKGT
Reserved
Name
D7
D6
Read returns zero.
RING Leakage Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
TIP Leakage Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
Monitor ADC Calibration.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
DAC Offset Calibration.
Calibrates the audio DAC offset.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
ADC Offset Calibration.
Calibrates the audio ADC offset.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
Common Mode Balance Calibration.
Calibrates the ac longitudinal balance.
0 = Normal operation or calibration complete.
1 = Calibration enabled or in progress.
CALLKGR
R/W
D5
CALLKGT
Preliminary Rev. 0.96
R/W
D4
CALMADC CALDACO CALADCO CALCMBAL
R/W
D3
Function
R/W
D2
R/W
D1
Si3232
R/W
D0
65

Related parts for SI3200-G-GS