7.5 Line Control Register (LCR)
The Line Control Register is used to specify the asynchronous data communication
format. The word length, the number of stop bits, and the parity are selected by writing the
appropriate bits in this register.
Table 15:
Bit
7
6
5
4
3
2
1:0
Line Control Register bits description
Symbol
LCR[7]
LCR[6]
LCR[5]
LCR[4]
LCR[3]
LCR[2]
LCR[1:0]
5 V, 3.3 V and 2.5 V quad UART, 5 Mbit/s (max.) with 64-byte FIFOs
Rev. 02 — 20 June 2005
Description
Divisor latch enable. The internal baud rate counter latch and Enhance
Feature mode enable.
Set break. When enabled, the Break control bit causes a break
condition to be transmitted (the TX output is forced to a logic 0 state).
This condition exists until disabled by setting LCR[6] to a logic 0.
Set parity. If the parity bit is enabled, LCR[5] selects the forced parity
format. Programs the parity conditions; see
Even parity. If the parity bit is enabled with LCR[3] set to a logic 1,
LCR[4] selects the even or odd parity format.
Parity enable. Parity or no parity can be selected via this bit.
Stop bits. The length of stop bit is specified by this bit in conjunction with
the programmed word length; see
Word length bits 1, 0. These two bits specify the word length to be
transmitted or received; see
logic 0 = divisor latch disabled (normal default condition)
logic 1 = divisor latch and enhanced feature register enabled
logic 0 = no TX break condition (normal default condition)
logic 1 = forces the transmitter output (TX) to a logic 0 for alerting the
remote receiver to a line break condition
logic 0 = parity is not forced (normal default condition)
LCR[5] = logic 1 and LCR[4] = logic 0: parity bit is forced to a logical 1
for the transmit and receive data
LCR[5] = logic 1 and LCR[4] = logic 1: parity bit is forced to a logical 0
for the transmit and receive data
logic 0 = odd parity is generated by forcing an odd number of logic 1s
in the transmitted data. The receiver must be programmed to check
the same format (normal default condition).
logic 1 = even parity is generated by forcing an even number of
logic 1s in the transmitted data. The receiver must be programmed to
check the same format.
logic 0 = no parity (normal default condition)
logic 1 = a parity bit is generated during the transmission, receiver
checks the data and parity for transmission errors
logic 0 or cleared = default condition