MMA8453QR1 Freescale, MMA8453QR1 Datasheet - Page 11

no-image

MMA8453QR1

Manufacturer Part Number
MMA8453QR1
Description
Manufacturer
Freescale
Datasheet

Specifications of MMA8453QR1

Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMA8453QR1
Manufacturer:
FREESCALE
Quantity:
12 000
Part Number:
MMA8453QR1
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MMA8453QR1
0
Table 4. I
1. All values referred to VIH (min) and VIL (max) levels.
2. t
3. The maximum t
4. t
5. t
6. A Fast mode I
7. Cb = total capacitance of one bus line in pF.
8. The maximum t
2.3
Sensors
Freescale Semiconductor
SCL Clock Frequency
Bus Free Time between STOP and START Condition
Repeated START Hold Time
Repeated START Set-up Time
STOP Condition Set-up Time
SDA Data Hold Time
SDA Valid Time
SDA Valid Acknowledge Time
SDA Set-up Time
SCL Clock Low Time
SCL Clock High Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Pulse width of spikes on SDA and SCL that must be suppressed by input filter
Pull-up = 4.7 k
Pull-up = 4.7 k
Pull-up = 4.7 k
Pull-up = 1 k
Pull-up = 1 k
by a transition time.
automatically be the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the LOW period of the
SCL signal, it must output the next data bit to the SDA line t
specification) before the SCL line is released. Also the acknowledge timing must meet this set-up time
This allows series protection resistors to be connected in between the SDA and the SCL pins and the SDA/SCL bus lines without exceeding
the maximum specified t
HD;DAT
VD;DAT
VD;ACK
= time for Data signal from SCL LOW to SDA output (HIGH or LOW, depending on which one is worse).
2
is the data hold time that is measured from the falling edge of SCL, applies to data in transmission and the acknowledge.
= time for Acknowledgement signal from SCL LOW to SDA output (HIGH or LOW, depending on which one is worse).
C Slave Timing Values
I
2
Ω,
Ω
C Interface Characteristic
Ω,
Ω,
Ω,
2
, Cb = 400 pF
(4)
C device can be used in a Standard mode I
HD;DAT
Cb = 20 pF
f
for the SDA and SCL bus lines is specified at 300 ns. The maximum fall time for the SDA output stage t
Cb = 20 pF
Cb = 40 pF
Cb = 400 pF
(2)
could be 3.45 μs and 0.9 μs for Standard mode and Fast mode, but must be less than the maximum of t
(7) (8)
f
.
(5)
Parameter
(1)
2
C system, but the requirement t
r
(max) + t
SU;DAT
= 1000 + 250 = 1250 ns (according to the Standard mode I
Symbol
t
t
t
t
t
t
t
HD;STA
SU;STA
SU;STO
HD;DAT
VD;DAT
VD;ACK
SU;DAT
t
t
t
f
HIGH
LOW
SCL
BUF
t
SP
t
t
r
f
SU;DAT
250 ns must then be met. This will
100
Min
1.3
0.6
0.6
0.6
4.7
50
0
0
0
0
0
4
(6)
I
2
C Fast Mode
Non-functional
2.250
0.9
0.9
1000
Max
4.50
f
100
750
300
50
is specified at 250 ns.
(3)
(3)
(3)
VD;DAT
MMA8453Q
or t
MHz
MHz
Unit
kHz
kHz
μs
μs
μs
μs
μs
μs
μs
ns
μs
μs
ns
ns
ns
VD;ACK
2
C
11