ISL1219IUZ Intersil, ISL1219IUZ Datasheet

IC RTC LP BATT BACK SRAM 10MSOP

ISL1219IUZ

Manufacturer Part Number
ISL1219IUZ
Description
IC RTC LP BATT BACK SRAM 10MSOP
Manufacturer
Intersil
Type
Clock/Calendar/NVSRAMr
Datasheets

Specifications of ISL1219IUZ

Memory Size
2B
Time Format
HH:MM:SS (12/24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Clock Format
HH
Clock Ic Type
RTC
Interface Type
I2C, Serial
Memory Configuration
2 X 8
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
MSOP
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL1219IUZ
Manufacturer:
Intersil
Quantity:
490
Part Number:
ISL1219IUZ
Manufacturer:
Intersil
Quantity:
222
Part Number:
ISL1219IUZ-T
Manufacturer:
INTERSIL
Quantity:
20 000
Low Power RTC with Battery Backed
SRAM and Event Detection
The ISL1219 device is a low power real time clock with
Event Detect and Time Stamp function, timing and crystal
compensation, clock/calendar, power fail indicator, periodic
or polled alarm, intelligent battery backup switching and 2
Bytes of battery-backed user SRAM.
The oscillator uses an external, low-cost 32.768kHz crystal.
The real time clock tracks time with separate registers for
hours, minutes, and seconds. The device has calendar
registers for date, month, year and day of the week. The
calendar is accurate through 2099, with automatic leap year
correction.
Ordering Information
NOTE: Intersil Pb-free products employ special Pb-free material sets;
molding compounds/die attach materials and 100% matte tin plate
termination finish, which are RoHS compliant and compatible with both
SnPb and Pb-free soldering operations. Intersil Pb-free products are
MSL classified at Pb-free peak reflow temperatures that meet or
exceed the Pb-free requirements of IPC/JEDEC J STD-020.
Pinout
ISL1219IUZ
ISL1219IUZ-T 1219Z
(See Note)
NUMBER
PART
V
EVIN
GND
MARKING
1219Z
BAT
X1
X2
PART
3
1
2
4
5
(10 LD MSOP)
2.7V to 5.5V -40 to +85 10 Ld MSOP
2.7V to 5.5V -40 to +85 10 Ld MSOP
TOP VIEW
ISL1219
RANGE
®
V
DD
1
Data Sheet
RANGE
10
9
8
7
6
TEMP
(°C)
V
IRQ/F
SCL
SDA
EVDET
DD
OUT
Tape and Reel
PACKAGE
(Pb-Free)
1-888-INTERSIL or 1-888-468-3774
Real Time Clock/Calendar with Event Detection
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
Features
• Real Time Clock/Calendar
• Security and Event Functions
• 15 Selectable Frequency Outputs
• Single Alarm
• Automatic Backup to Battery or Super Cap
• Power Failure Detection
• On-Chip Oscillator Compensation
• 2 Bytes Battery-Backed User SRAM
• I
• 400nA Battery Supply Current
• Small Package
• Pb-Free Plus Anneal Available (RoHS Compliant)
Applications
• Utility Meters
• Set Top Box/Modem
• POS Equipment
• Network Routers, Hubs, Switches, Bridges
• Cellular Infrastructure Equipment
• Fixed Broadband Wireless Equipment
• Test Meters/Fixtures
• Vending Machine Management
• Security and Anti Tampering Applications
- Tracks Time in Hours, Minutes, and Seconds
- Day of the Week, Day, Month, and Year
- Tamper detection with Time Stamp in Normal and
- Event Detection During Battery Backed or Normal
- Selectable Event Input Sampling Rates Allows Low
- Selectable Glitch Filter on Event Input Monitor
- Settable to the Second, Minute, Hour, Day of the Week,
- Single Event or Pulse Interrupt Mode
- 400kHz Data Transfer Rate
- 10 Ld MSOP
- Panel/Enclosure Status
- Warranty Reporting
- Time Stamping Applications
- Patrol/Security Check (Fire or Light Equipment)
- Automotive Applications
2
C Interface
Battery Backed modes
Modes
Power Operation
Day, or Month
August 14, 2006
All other trademarks mentioned are the property of their respective owners.
|
Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright Intersil Americas Inc. 2006. All Rights Reserved
ISL1219
FN6314.1

Related parts for ISL1219IUZ

ISL1219IUZ Summary of contents

Page 1

... RANGE ISL1219IUZ 1219Z 2.7V to 5.5V - MSOP ISL1219IUZ-T 1219Z 2.7V to 5.5V - MSOP NOTE: Intersil Pb-free products employ special Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate termination finish, which are RoHS compliant and compatible with both SnPb and Pb-free soldering operations ...

Page 2

Block Diagram SDA SDA BUFFER SCL SCL BUFFER X1 CRYSTAL OSCILLATOR TRIP V BAT EVIN GND Pin Descriptions PIN NUMBER SYMBOL 1 X1 X1. The X1 pin is the input of an inverting amplifier and is ...

Page 3

Absolute Maximum Ratings Voltage SCL, SDA, and IRQ/F DD BAT (respect to ground ...

Page 4

Power-Down Timing Test Conditions: V SYMBOL PARAMETER V V Negative Slew Rate DD SR Interface Specifications Test Conditions: V SYMBOL PARAMETER V SDA and SCL Input Buffer LOW IL Voltage V SDA and SCL Input Buffer ...

Page 5

I C Interface Specifications Test Conditions: V SYMBOL PARAMETER t SDA and SCL Fall Time F Cb Capacitive Loading of SDA or SCL Rpu SDA and SCL Bus Pull-up Resistor Off-chip NOTES: 2. IRQ and F and EVDET Inactive. ...

Page 6

VDD Typical Performance Curves 1E-6 900E-9 800E-9 700E-9 600E-9 500E-9 400E-9 300E-9 200E-9 100E-9 000E+0 1.5 2.0 2.5 3.0 3.5 4.0 V (V) BAT FIGURE BAT 2.4E-06 2.2E- 2.0E-06 1.8E-06 1.6E-06 V ...

Page 7

Typical Performance Curves ...

Page 8

... Functional Description Power Control Operation The power control circuit accepts a V Many types of batteries can be used with Intersil RTC products. For example, 3.0V or 3.6V Lithium batteries are appropriate, and battery sizes are available that can power the ISL1219 for years. Another option is to use a Super Cap for applications where month ...

Page 9

These power control situations are illustrated in Figures 11 and 12. BATTERY BACKUP MODE TRIP V BAT BAT BATHYS FIGURE 11. BATTERY SWITCHOVER WHEN V BATTERY BACKUP MODE BAT V TRIP ...

Page 10

Event Detect Timing Diagram With Sampling Mode Enabled Case 1, Switched Opened Before I 15 CLKS (8x OFF OPEN EXT. SWITCH CLOSED HIGH EV IN LOW HIGH EVDET LOW 8 CLKS (8x) Case 2, Switched Opened After ...

Page 11

Accuracy of the Real Time Clock The accuracy of the Real Time Clock depends on the frequency of the quartz crystal that is used as the time base for the RTC. Since the resonant frequency of a crystal is temperature ...

Page 12

A sequential read will not result in the output of data from the memory array. At the end of ...

Page 13

Real Time Clock Registers Addresses [00h to 06h] RTC REGISTERS (SC, MN, HR, DT, MO, YR, DW) These registers depict BCD representations of the time. As such, SC (Seconds) and MN (Minutes) range from 0 to 59, HR (Hour) can ...

Page 14

STOP condition during a valid write cycle. CRYSTAL OSCILLATOR ENABLE BIT (XTOSCB) This bit enables/disables the internal crystal oscillator. When the XTOSCB is set to “1”, the oscillator is disabled, and the X1 pin ...

Page 15

EVENT DETECTION REGISTER (EV) The ISL1219 provides an easy to use event and tamper detection circuit. The Event Detection Register configures the functionality of the event detection circuits. EVENT INPUT SAMPLING SELECTION BITS (ESMP<1:0>) These two bits select the rate ...

Page 16

For example, C (ATR = 00000) = 12.5pF, LOAD C (ATR = 100000) = 4.5pF, and C LOAD = 20.25pF. The entire range for the series combination of load capacitance goes from 4.5pF to 20.25pF in 0.25pF steps. Note that ...

Page 17

Below are examples of both Single Event and periodic Interrupt Mode alarms. Example 1 – Alarm set with single interrupt (IM = ”0”) A single alarm will occur on January 1 at 11:30am. A. Set Alarm registers as follows: BIT ...

Page 18

Protocol Conventions Data states on the SDA line can change only during SCL LOW periods. SDA state changes during SCL HIGH are reserved for indicating START and STOP conditions (See Figure 14). On power up of the ISL1219, the SDA ...

Page 19

Device Addressing Following a start condition, the master must output a Slave Address Byte. The 7 MSBs are the device identifier. These bits are “1101111”. Slave bits “1101” access the register. Slave bits “111” specify the device select bits. The ...

Page 20

Application Section Event Detection The event detection feature of the ISL1219 is intended to be used for recording the time of single events that involve the opening of an enclosure, door, etc. The normal method of detection is with normally ...

Page 21

The most appropriate use for the hysteresis function is for glitch or noise filtering on the EVIN input signal. Battery Backup Details The event detection function has been designed to minimize power drain for extended life in ...

Page 22

Temperature Compensation The ATR and DTR controls can be combined to provide crystal drift temperature compensation. The typical 32.768kHz crystal has a drift characteristic that is similar to that shown in Figure 20. There is a turnover temperature (T ) ...

Page 23

In addition good idea to avoid a ground plane under the X1 and X2 pins and the crystal, as this will affect the load capacitance and therefore the oscillator accuracy of the circuit. If the ~IRQ/F pin ...

Page 24

C = 0.47F BAT V = 4.7V BAT2 V = 1.8V BAT1 (assumed minimal) LKG Solving equation 4 for this example, I BATAVG T = 0.47 * (2.9) / 4.38E-7 = 3.107E6 sec BACKUP Since there ...

Page 25

... Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use ...

Related keywords