3.3 INSTALLATION
1.
2.
∗ Use the spacers depending on the fitting panel thickness referring to the next table. If not,
∗ The screw torque is 49 cN m (5 kgf cm).
[Note] Do not touch the end of the DC plug.
How to Install the Fixing Bracket
Setting Paper
(1) Press the paper cover open button, and open the paper cover.
(2) Set a paper roll as shown in the figure.
(3) Close the paper cover by pressing both ends of the cover so the tip end of the paper will
the body may be deformed, and therefore it may be hard to open the paper cover or printing
quality may be deteriorated. (If the fitting panel thickness exceeds 2.2 mm, it may be hard to
tighten the screws.)
Panel thickness
1.0 mm
1.2 mm
1.5 to 1.6 mm
be emerged from the printer.
Handle the paper cutter carefully not to cut your hand.
Figure 3-5 Installing the Fixing Bracket
None
0.2 mm
0.5 mm
thickness
Spacer
Use the spacers as much as you need
スペー サー を必要 なぶ ん重ね て使 用す る。
3-4
Panel thickness
1.7 to 1.8 mm
2.0 mm
2.2 mm
0.5 mm and 0.2 mm
1.0 mm
1.0 mm and 0.2 mm
Spacer thickness