9. Bitimage commands
ESC ∗ m nl nh [d1...dk]
Domain of
Function
function
Details
Code
1B
m = 0,1,32,33
0 ≤ nl ≤ 255
0 ≤ nh ≤ 3
0 ≤ d ≤ 255
Specifies the Bitimages with the number of dots specified as nl and nh in Mode m.
• If m is out of the domain of function, the data after nl is processed as the normal
• nl and nh mean the number of dots in the horizontal direction of the Bitimage to
• If the dot is specified beyond the printable area, the data is deleted.
• The data deployment position corresponds to the deployment start position.
• This command is affected by the inverse print but the others such as dual print,
• Refer to the diagram for how to deploy the data.
32
33
data.
be printed.
bold print and reverse print.
m
0
1
16
+ 2A
24 dot double density
24 dot single density
8 dot double density
8 dot single density
16
+ m + nl + nh + [d1...dk]
Mode
Bitimage Select
5-38
The number
the vertical
of dots in
direction
24
24
8
8
The number of
dots in the
horizontal
direction
(1 line)
192
384
192
384
(nh × 256 + nl) × 3
(nh × 256 + nl) × 3
The number of
nh × 256 + nl
nh × 256 + nl
data (k)