3. Form commands
ESC 2
ESC 3 n
ESC SP n
Domain of
Domain of
Function
Function
Function
function
function
Details
Details
Code
Code
Code
0 ≤ n ≤ 255
• The default amount of paper feed for one line, n = 28.
0 ≤ n ≤ 127
1B
Restores the amount of paper feed for one line to its default value.
1B
Sets the amount of paper feed for one line at [n × dot pitch].
1B
Sets the character spacing for standard size character at [n × dot pitch].
• The right character spacing increases depending on the horizontal scaling factor.
• This command does not affect kanji.
• In default, n = 0.
16
16
16
+ 32
+ 33
+ 20
16
16
16
+ n
+ n
Default Amount of Line Spacing Specify
Amount of Line Spacing Set
Standard Size Character Right Spacing Set
5-16