DPU-30-0B-E Seiko Instruments, DPU-30-0B-E Datasheet - Page 62

no-image

DPU-30-0B-E

Manufacturer Part Number
DPU-30-0B-E
Description
Printers PNL MNT 58MM EZ-OP
Manufacturer
Seiko Instruments
Datasheet

Specifications of DPU-30-0B-E

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
8. Response commands (only for serial mode)
GS a n
Domain of
Function
function
Details
Code
Validity / Invalidity of Automatic Status Transmission and Real Time Command Select
0 ≤ n ≤ 3
Specifies the validity or invalidity of the automatic status response which is one of
the printer statuses.
Specifies the validity or invalidity of the real time command.
n = 0: The automatic status response becomes invalid.
n = 1: The automatic status response becomes valid. And the current status is
n = 2: The real time command becomes invalid.
n = 3: The real time command becomes valid
1D
• The automatic status response automatically returns a response depending on
• The real time command is executed at the reception.
• For the status values, refer to Table 5-1 Status Response Value Table.
• This command is executed at the deployment of the receive buffer so that the
• When a value is returned, the conditions of the host computer are not checked.
• In default, both the automatic status response and the real time command are
the change in status.
execution of the command may be delayed depending on the conditions of the
receive buffer.
invalid.
16
+ 61
returned.
16
+ n
5-34

Related parts for DPU-30-0B-E