SA56004DD NXP Semiconductors, SA56004DD Datasheet - Page 16

Board Mount Temperature Sensors I2C LOC +/- 2OC AND REM +/- 1OC TS

SA56004DD

Manufacturer Part Number
SA56004DD
Description
Board Mount Temperature Sensors I2C LOC +/- 2OC AND REM +/- 1OC TS
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SA56004DD

Full Temp Accuracy
+/- 1 C, +/- 3 C
Package / Case
SOT-96
Digital Output - Bus Interface
I2C
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SA56004DD,112
NXP Semiconductors
SA56004X_5
Product data sheet
7.9.3 Fault Queue
To suppress erroneous ALERT or T_CRIT triggering, the SA56004X implements a Fault
Queue for both local and remote channel. The Fault Queue insures a temperature
measurement is genuinely beyond a HIGH, LOW or T_CRIT setpoint by not triggering
until three consecutive out-of-limit measurements have been made. The fault queue
defaults OFF upon POR and may be activated by setting bit 0 in the Configuration register
(address 09h) to logic 1.
Fig 8.
Event C: The Status register bit 1 (RCRIT) is reset by a read of the Status register (in
the interrupt mode).
Event A: The remote temperature has exceeded the Remote HIGH setpoint.
Event B: Three consecutive over limit measurements have been made exceeding the
Remote HIGH setpoint; the ALERT output is activated (goes LOW). By now, the remote
temp has exceeded the Remote T_CRIT setpoint (RCS).
Event C: Three consecutive over limit measurements have been made exceeding RCS;
the T_CRIT output is activated (goes LOW).
Event D: The remote temperature falls below the RCS
Event E: The ALERT output is de-activated (goes HIGH) after a below_high_limit
temperature measurement is completed.
remote HIGH setpoint
remote LOW setpoint
Remark: All events indicate the completion of a conversion.
Fault queue remote HIGH and LOW and T_CRIT, T_CRIT hysteresis setpoint
response (comparator mode)
T_CRIT output
ALERT output
RCS
events
RCS
TH
Rev. 05 — 22 May 2008
A
Digital temperature sensor with overtemperature alarms
B
C
remote temperature
D
E
F
TH setpoint.
G
SA56004X
H
© NXP B.V. 2008. All rights reserved.
002aad218
I
16 of 36

Related parts for SA56004DD