BMR4540000/001 Ericsson Power Modules, BMR4540000/001 Datasheet - Page 3

DC/DC Converters & Regulators 12V 20A 240W Bus Converter

BMR4540000/001

Manufacturer Part Number
BMR4540000/001
Description
DC/DC Converters & Regulators 12V 20A 240W Bus Converter
Manufacturer
Ericsson Power Modules
Datasheet

Specifications of BMR4540000/001

Output Power
240 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
12 V
Output Current (channel 1)
20 A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
E
Prepared (also subject responsible if other)
SEC/S Kevin Zhou
Approved
BMR454 series Fully regulated Intermediate Bus Converters
Input 36-75 V, Output up to 40 A / 240 W
Warranty
Warranty period and conditions are defined in Ericsson
Power Modules General Terms and Conditions of Sale.
Limitation of Liability
Ericsson Power Modules does not make any other
warranties, expressed or implied including any warranty of
merchantability or fitness for a particular purpose (including,
but not limited to, use in life support applications, where
malfunctions of product can cause injury to a person’s
health or life).
© Ericsson AB 2011
The information and specifications in this technical
specification is believed to be correct at the time of
publication. However, no liability is accepted for
inaccuracies, printing errors or for any consequences
thereof. Ericsson AB reserves the right to change the
contents of this technical specification at any time without
prior notice.
Safety Specification
General information
Ericsson Power Modules DC/DC converters and DC/DC
regulators are designed in accordance with safety
standards IEC/EN/UL 60950-1 Safety of Information
Technology Equipment.
IEC/EN/UL 60950-1 contains requirements to prevent
injury or damage due to the following hazards:
On-board DC/DC converters and DC/DC regulators are
defined as component power supplies. As components
they cannot fully comply with the provisions of any safety
requirements without “Conditions of Acceptability”.
Clearance between conductors and between conductive
parts of the component power supply and conductors on
the board in the final product must meet the applicable
safety requirements. Certain conditions of acceptability
apply for component power supplies with limited stand-off
(see Mechanical Information for further information). It is
the responsibility of the installer to ensure that the final
product housing these components complies with the
requirements of all applicable safety standards and
regulations for the final product.
Component power supplies for general use should comply
with the requirements in IEC 60950-1, EN 60950-1 and
UL 60950-1 Safety of Information Technology Equipment.
There are other more product related standards, e.g.
Electrical shock
Energy hazards
Fire
Mechanical and heat hazards
Radiation hazards
Chemical hazards
Checked
Ericsson Internal
PRODUCT SPECIFICATION
No.
1/1301- BMR 454 Uen
Date
2011-05-05
IEEE 802.3 CSMA/CD (Ethernet) Access Method, and
ETS-300132-2 Power supply interface at the input to
telecommunications equipment, operated by direct current
(dc), but all of these standards are based on
IEC/EN/UL 60950-1 with regards to safety.
Ericsson Power Modules DC/DC converters and DC/DC
regulators are UL 60950-1 recognized and certified in
accordance with EN 60950-1.
The flammability rating for all construction parts of the
products meet requirements for V-0 class material
according to IEC 60695-11-10, Fire hazard testing, test
flames – 50 W horizontal and vertical flame test methods.
The products should be installed in the end-use equipment,
in accordance with the requirements of the ultimate
application. Normally the output of the DC/DC converter is
considered as SELV (Safety Extra Low Voltage) and the
input source must be isolated by minimum Double or
Reinforced Insulation from the primary circuit (AC mains) in
accordance with IEC/EN/UL 60950-1.
Isolated DC/DC converters
It is recommended that a slow blow fuse is to be used at
the input of each DC/DC converter. If an input filter is used
in the circuit the fuse should be placed in front of the input
filter.
In the rare event of a component problem that imposes a
short circuit on the input source, this fuse will provide the
following functions:
The galvanic isolation is verified in an electric strength test.
The test voltage (V
1500 Vdc or 2250 Vdc (refer to product specification).
24 V DC systems
The input voltage to the DC/DC converter is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
48 and 60 V DC systems
If the input voltage to the DC/DC converter is 75 Vdc or
less, then the output remains SELV (Safety Extra Low
Voltage) under normal and abnormal operating conditions.
Single fault testing in the input power supply circuit should
be performed with the DC/DC converter connected to
demonstrate that the input voltage does not exceed
75 Vdc.
Isolate the fault from the input power source so as
not to affect the operation of other parts of the
system.
Protect the distribution wiring from excessive
current and power loss thus preventing hazardous
overheating.
Technical Specification
EN/LZT 146 404 R4B May 2011
© Ericsson AB
Rev
G
iso
) between input and output is
Reference
3 (5)
3

Related parts for BMR4540000/001