UDT020A0X3-SRZ Lineage Power, UDT020A0X3-SRZ Datasheet - Page 25

DC/DC Converters & Regulators 3-14.4Vin .6-5.5Vout 20A Neg SMT Digital

UDT020A0X3-SRZ

Manufacturer Part Number
UDT020A0X3-SRZ
Description
DC/DC Converters & Regulators 3-14.4Vin .6-5.5Vout 20A Neg SMT Digital
Manufacturer
Lineage Power
Datasheet

Specifications of UDT020A0X3-SRZ

Product
Non-Isolated / POL
Input Voltage Range
3 VDC to 14.4 VDC
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.6 VDC to 5.5 VDC
Output Current (channel 1)
20 A
Output Voltage
0.6 VDC to 5.5 VDC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Preliminary Data Sheet
May 10, 2011
Summary of Supported PMBus Commands
Please refer to the PMBus 1.1 specification for more details of these commands.
LINEAGE
Code
Hex
01
02
03
10
11
12
13
14
20
RESTORE_DEFAULT_CODE
RESTORE_DEFAULT_ALL
STORE_DEFAULT_CODE
POWER
STORE_DEFAULT_ALL
ON_OFF_CONFIG
WRITE_PROTECT
CLEAR_FAULTS
VOUT_MODE
OPERATION
Command
3 – 14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A output current
20A Digital Micro DLynx
Turn Module on or off. Also used to margin the output voltage
Configures the ON/OFF functionality as a combination of analog ON/OFF
pin and PMBus commands
Clear any fault bits that may have been set, also releases the SMBALERT#
signal if the device has been asserting it.
Used to control writing to the module via PMBus. Copies the current register
setting in the module whose command code matches the value in the data
byte into non-volatile memory (EEPROM) on the module
Bit5: 0 – Enables all writes as permitted in bit6 or bit7
Bit 6: 0 – Enables all writes as permitted in bit5 or bit7
Bit7: 0 – Enables all writes as permitted in bit5 or bit6
Copies all current register settings in the module into non-volatile memory
(EEPROM) on the module
Restores all current register settings in the module from values in the
module non-volatile memory (EEPROM)
Copies the current register setting in the module whose command code
matches the value in the data byte into non-volatile memory (EEPROM) on
the module
Restores the current register setting in the module whose command code
matches the value in the data byte from the value in the module non-volatile
memory (EEPROM)
The module has MODE set to Linear and Exponent set to -10. These values
cannot be changed
Default Value
Default Value
Default Value
Default Value
Bit Position
Bit Position
Bit Position
Bit Position
Bit Position
Bit Position
Function
Function
Function
Function
Function
Function
1 – Disables all writes except the WRITE_PROTECT, OPERATION
1 – Disables all writes except for the WRITE_PROTECT command
Access
Access
Access
Access
Access
Access
Format
Format
Format
1 – Disables all writes except for the WRITE_PROTECT and
and ON_OFF_CONFIG (bit 6 and bit7 must be 0)
(bit5 and bit6 must be 0)
OPERATION commands (bit5 and bit7 must be 0)
Table 6
bit7
r/w
On
r/w
X
w
w
7
0
7
0
7
0
7
7
7
0
r
r
Mode
bit6
r/w
X
X
w
w
6
0
6
0
6
0
6
6
6
0
r
r
r
Brief Description
TM
: Non-isolated DC-DC Power Modules
bit5
r/w
r/w
X
w
w
5
0
5
0
5
0
5
5
5
0
r
r
Unsigned Binary
Unsigned Binary
Unsigned Binary
Command code
Command code
r/w
r/w
pu
w
w
4
0
4
1
4
X
X
4
4
4
1
x
r
Margin
cmd
r/w
r/w
w
w
3
0
3
0
3
X
X
3
3
3
0
x
r
Exponent
r/w
r/w
pol
X
X
w
w
2
0
2
1
2
x
2
2
2
1
r
cpa
r/w
X
X
X
X
w
w
1
1
1
1
x
1
1
1
1
r
r
X
X
X
X
X
w
w
0
0
1
0
x
0
0
0
0
r
r
r
Non-Volatile
Memory
Storage
YES
YES
25

Related parts for UDT020A0X3-SRZ