H5CX-L8-N AC100-240 Omron Automation, H5CX-L8-N AC100-240 Datasheet - Page 10

no-image

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; Socket Mnt; 8 Pin
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-L8-N AC100-240

Brand/series
H5CX
Connection Type
8 Pin Socket
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 62.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush, Surface or Din Rail
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
10
1. Key Protect Indicator
2. Control Output Indicator
3. Reset Indicator
4. Present Value Display
5. Time Unit Indicators
6. Set Value Display
7. Set Value 1, 2 Indicator
H5CX-A@-N/-L@-N
Nomenclature
Dimensions
Digital Timers
Digital Timers
H5CX-A-N/-AS-N (Flush Mounting Models)
H5CX-A11@-N
(Flush Mounting/Surface Mounting Models)
(Character height: 12 mm, red
* Characters on models with screw terminals
(Color is same as present value display.)
(If the time range is 0 min, 0 h, 0.0 h, or 0 h
0 min, these indicators flash to indicate
timing operation.)
(Character height: 6 mm, green)
Character Size
for Present
Value Display
(H5CX-A@) can be switched between red,
green, and orange.
48×48
48×48
12mm
Display Section
Note: M3.5 terminal screw (effective length: 6 mm)
Character Size
for Set Value
Display
(orange)
6
6
(Sub-display)
6mm
(orange)
(Main display)
(green)
*
)
(orange)
63.7
78
14.4
44.8×44.8
44.8×44.8
12
1
2
3
8
9
Front View
H5CX-AD-N/-ASD-N (Flush Mounting Models)
H5CX-L8@-N (Flush Mounting/Surface Mounting Models)
48×48
48×48
Note: M3.5 terminal screw (effective length: 6 mm)
10
11
13
4
5
6
7
6
6
8. Mode Key
9. Reset Key
10. Up Keys 1 to 4
11. Down Keys 1 to 4
12. Key-protect Switch
13. DIP Switch
(Changes modes and setting items)
(Resets present value and output)
Note: There is no DIP switch on the
(Default setting)
OFF
ON
59
63.7
H5CX-L8@.
1 2 3 4 5 6 7 8
Operation Key
(Disabled)
Switches
OFF
44.8×44.8
14.2
44.8×44.8
(Enabled)
(unit: mm)
ON

Related parts for H5CX-L8-N AC100-240