H5CX-L8-N AC100-240 Omron Automation, H5CX-L8-N AC100-240 Datasheet - Page 21

no-image

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; Socket Mnt; 8 Pin
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-L8-N AC100-240

Brand/series
H5CX
Connection Type
8 Pin Socket
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 62.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush, Surface or Din Rail
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
Mode b: Repeat cycle 1 (Timer resets when power comes ON.)
Basic operation
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
Mode b-1: Repeat cycle 2 (Timer does not reset when power comes ON.)
Basic operation
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The control output is turned ON when time is up.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
Start signal
Start signal
Start signal
Start signal
Output
Output
Output
Output
Power
Power
Power
Power
input
input
input
input
the set time is too short.
Set the value to at least 100 ms (contact
output type).
the set time is too short.
Set the value to at least 100 ms (contact
output type).
the set time is too short.
Set the value to at least 100 ms (contact
output type).
the set time is too short.
Set the value to at least 100 ms (contact
output type).
*
*
*
*
Timing
Timing
Timing
Timing
Timing Sustained Timing
Timing Sustained Timing
Timing
Timing
Timing
Timing
Timing
Timing
Timing
Timing
Timing
Timing
Detailed operation
Sustained Output
One-shot Output
Detailed operation
Sustained Output
One-shot Output
Control output
Control output
Control output
Control output
Start signal
Start signal
Start signal
Start signal
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
Set value
Set value
Set value
Set value
Set value
Set value
Set value
Set value
Power
Power
Power
Power
Reset
Reset
Reset
Reset
Gate
Gate
Gate
Gate
0
0
0
0
0
0
0
0
t
t
t
t
t
H5CX-A@-N/-L@-N
t
Timer
t
21

Related parts for H5CX-L8-N AC100-240