H5CX-L8-N AC100-240 Omron Automation, H5CX-L8-N AC100-240 Datasheet - Page 40

no-image

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; Socket Mnt; 8 Pin
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-L8-N AC100-240

Brand/series
H5CX
Connection Type
8 Pin Socket
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 62.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush, Surface or Din Rail
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
40
H5CX-B@-N
Timing Charts
Note: 1. The forecast value = set value - forecast set value
Mode A: Signal ON delay (Timer resets when power comes ON.)
Basic operation
* Start signal input is disabled during timing.
• Timing starts when the start signal goes ON.
• While the start signal is ON, the timer starts when the
• A sustained control output is used.
• Timing stops when the time is up.
Note: Output is instantaneous when the set value is 0.
Mode F-1: Cumulative (Timer does not reset when power comes ON.)
Basic operation
• Start signal enables timing (timing is stopped when the
• A sustained control output is used.
• Timing continues even after the time is up.
Note: Output is instantaneous when the set value is
When the H5CX is used with power start in mode F
mode or F-1 (i.e., cumulative operation with output on
hold), there will be a timer error (approximately 100
ms each time the H5CX is turned ON) due to the
characteristics of the internal circuitry. Use the H5CX
with signal start if timer accuracy is required.
Forecast
Forecast
Control
Control
power comes ON or when the reset input goes OFF.
start signal is OFF or when the power is OFF).
output
output
output
output
OUT1
OUT2
( ) The names in parentheses are used for the absolute value setting.
OUT1
OUT2
( ) The names in parentheses are used for the absolute value setting.
Start signal input
Start signal input
2. The forecast set value is used to set the deviation for the set value.
(
(
(
(
0.
Control
output 1
Control
output 2
Control
output 1
Control
output 2
OUT1
OUT2
OUT1
OUT2
Power
Power
)
)
)
)
*
Timing
Sustained
Timing
Timing
Detailed operation
Detailed operation
Set value (SV 2)
Forecast value
The names in parentheses are used for the absolute value setting.
The names in parentheses are used for the absolute value setting.
Start signal
999999
Set value (SV 2)
(SV 1)
OUT1
OUT2
Power
Forecast value
Reset
Gate
0
Start signal
999999
(SV 1)
OUT1
OUT2
Power
Reset
Gate
0

Related parts for H5CX-L8-N AC100-240