VQ1101N-51 SMC Corporation, VQ1101N-51 Datasheet - Page 66

no-image

VQ1101N-51

Manufacturer Part Number
VQ1101N-51
Description
VALVE; SOLENOID; 6 MM; 15 W (MAX.); 24 VDC; 2 POSITION SINGLE; METAL; 0.5 MPA
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQ1101N-51

Brand/series
VQ Series
Configuration
2-Position Single
Enclosure Rating
IP65
Fluid Type
Air/Inert Gas
Pressure, Operating
0.7 MPa
Primary Type
Solenoid Valve
Temperature, Ambient
–10° to +50°C
Valve Type
5-Port Solenoid, Plug-In, Base Mounted with 2 Position Actuation, Rubber Seal, Negative Common
Voltage, Coil
24 VDC
Series
VQ1000: Manifold Optional Parts
Blanking plate assembly
VVQ1000-10A-1
It is used by attaching on the manifold block for being
prepared for removing a valve for maintenance rea-
sons or planning to mount a spare valve, etc.
Individual SUP spacer
VVQ1000-P-1-
When the same manifold is to be used for different pres-
sures, individual SUP spacers are used as SUP ports for
different pressures. (One station space is occupied.)
Block both sides of the station, for which the supply
pressure from the individual SUP spacer is used, with
SUP block plates. (Refer to the application example.)
Individual EXH spacer
VVQ1000-R-1-
When valve exhaust affects other stations due to the
circuit configuration, this spacer is used for individual
valve exhaust. (One station space is occupied.)
Block both sides of the individual valve EXH station.
(Refer to the application example.)
SUP block plate
VVQ1000-16A
When different pressures are supplied to a manifold, a
SUP block plate is used to block the stations under dif-
ferent pressures.
<Block indication label>
Indication labels to confirm the blocking position are at-
tached (Each for SUP passage and SUP/EXH passage
blocking positions).
Blanking plate with connector
VVQ1000-1C -
Blanking plate with a connector for individually outputting electricity to
drive a single valve or equipment that are not on the manifold base.
Note) Electric current should be 1A or less (including the mounted valves).
65
position by means of the manifold specification sheet.
The block plate is used in one or two places for one set.
(Two SUP block plates for blocking SUP station are
attached to the individual SUP spacer.)
manifold station where the individual SUP spacer is mounted.
spacers, enter “X” in the special wiring specifications
column in the manifold specification sheet.
block base or EXH block plate position by means of
the manifold specification sheet. The block plate is
used in one or two places for one set.
position when ordering an EXH spacer incorporated
with a manifold no. However, do not order an EXH
block base assembly because it is attached to the
spacer.
When separately ordering an individual EXH spacer,
separately order an EXH block base assembly be-
cause it is not attached to the spacer.
ition of the manifold station where the individual EXH
spacer is mounted.
spacers, enter “X” in the special wiring specifications
column in the manifold specification sheet.
Specify the mounting position by means of the mani-
fold specification sheet.
manifold, a block indication label is attached to the
manifold.
ferent from a standard shape.
Specify the spacer mounting position and SUP block plate
As a standard, electric wiring is connected to the position of the
An EXH block base assembly is used in the blocking
As a standard, electric wiring is connected to the pos-
When “N” is suffixed to the end of the name plate, the plate will be dif-
If wiring is not required for stations equipped with
Specify the mounting position, as well as the EXH
When ordering a block plate incorporated with a
Nil
If wiring is not required for stations equipped with
1
2
With connector/2-wire
With connector/4-wire
Without connector
Connector
VQ1000
C6
N7
C6
N7
Connector lead wire length (mm)
Nil
10
15
6
JIS symbol
1000
1500
300
600
JIS symbol
20
25
30
EXH
passage
blocked
EXH block
base assembly
2000
2500
3000
SUP block plate
Blanking
plate with
connector
Individual EXH spacer
C6 (EXH port)
C6: ø6 one-touch fitting
Individual SUP spacer
SUP passage blocked
Connector on the power
supply side is not attached.
Block indication label
A label indicating the EXH
passage blocking position
is to be adhered.
C6 (SUP port)
C6: ø6 one-touch fitting
Block indication
label
A label indicating the SUP
passage blocking position
is to be adhered.
Block indication label
Connector
assembly
Description/Model
D side
Lead wire color: Black
Lead wire color: Red
Lead wire color: White
D side
SUP/EXH passage blocked
Single
Individual EXH spacer
VVQ1000-R-1-C6
EXH blocking position: Specify 2 places.
EXH block base assembly
Individual EXH spacer
Valve
Connector assembly part no.
AXT661-
Valve
SUP block plate
+
Individual
SUP spacer
(Not to be
ordered)
Stations
43
43
44
A-
24AWG
Cover O.D.
4-wire
2-wire
1
EXH block base assembly
6
Valve
Valve
2
ø
1.5
3
SUP block plate
Valve
(Not to be
ordered)
4
+
Lead wire
length (mm)
Nil
10
20
30
Valve
6
5
6
1000
2000
3000
U side
300
600
U side
7

Related parts for VQ1101N-51