Specifications of ES-TN-1H5

Coil Voltage Vdc Nom
24V
Contact Current Max
4A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
250V
Contact Configuration
SPST-NC
No. Of Poles
1
Relay Mounting
DIN Rail
External Height
85.5mm
E-Stop Safety Modules ES-TN-1H5 and -1H6 provide seven indicator LEDs
Power
(green)
Fault
(red)
E-Stop
(green)
Reset
(green)
Monitor
(green)
Out
(green)
Timed-out
(green)
Before performing the initial checkout
procedure, make certain all power is
disconnected from the machine to be
controlled. Dangerous voltages may be
present along the E-stop Safety Module
wiring barriers whenever power to
the machine control elements is ON.
Exercise extreme caution whenever
machine control power is or may be
present. Always disconnect power to
the machine control elements before
opening the enclosure housing of the
E-stop Safety Module.
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
E-Stop Safety Modules with Adjustable Delay
CAUTION . . .
Disconnect Power Prior
to Checkout
ON – Power is connected to terminals A1-A2
OFF – No power or low power to terminals A1-A2, or internal power supply failure
ON – External fault or configuration fault. The corresponding function LED (see below) will flash to indicate the area where the
Flashing – Internal Fault. See page 16 for repair.
ON – E-Stop inputs are closed (S11-S12 and S21-S22).
OFF – E-Stop inputs are open.
Flashing (Fault LED OFF) – If the Module is configured for Manual Power-up and Auto Reset, the E-Stop button must be cycled
Flashing (Fault LED ON) – See Fault Indication Table for probable cause.
ON – Reset input is closed (X1-X2).
OFF – Reset input is open.
Flashing (Fault LED OFF) – “Reset Requested.” The Reset input (button) must be cycled (closed, then opened), to enter
Flashing (Fault LED ON) – See Fault Indication Table for probable cause.
ON – Monitoring inputs are closed (X3-X4 and X5-X6).
OFF – Monitoring inputs are open.
Flashing (Fault LED ON) – See Fault Indication Table for probable cause.
ON – Both internal relays K1 and K2 are energized. (Immediate N.O. outputs 13-14 and 23-24 are closed. Immediate N.C. output
OFF – Both internal relays K1 and K2 are de-energized. (Immediate N.O. outputs 13-14 and 23-24 are open. Immediate N.C.
ON – Both internal relays K3 and K4 are energized. (Delayed N.O. outputs 37-38 and 47-48 are closed. Delayed N.C. output
OFF – Both internal relays K3 and K4 are de-energized. (Delayed N.O. outputs 37-38 and 47-48 are open. Delayed N.C. output
Flashing (Fault LED ON) – See Fault Indication Table for probable cause.
fault has been detected. See Fault Indication Table for probable cause.
51-52 is open.)
61-62 is open.)
output 51-52 is closed.)
61-62 is closed.)
(opened, then closed) to enter RUN mode. (Ensure Cancel Delay input is open or a fault will occur.)
RUN mode.
Minneapolis, MN U.S.A.
The functioning of the E-stop system must be verified periodically to ensure proper
operation (see also the machine manufacturer’s recommendations).
NOTE: If two or more E-stop switches are series-connected to one E-Stop Safety
Procedure:
1. With the machine running, engage the E-stop switch (open its contact). Verify that
2. Return the E-stop switch to its closed-contact position. Verify that the machine
3. Close and then open the Reset switch (if using manual reset mode). Verify that the
the machine stops.
does not restart.
machine restarts.
Module, this test must be individually run for EACH switch.