Operation
• Press the Set Key. The data will remain lit for approximately one second, the settings will be confirmed,
H Data Output Timing
• • • • 3F88L-160 (16-point Model)
• • • • For Present Value Outputs Set to “2” (4-digit Resolver Speed (No Units))
Note The output timing for each digit of display data (CAM 13 to 16) and each digit’s LE signal (CAM9 to
3-6-11 Pulse Output Function
H Function
• The pulse output function creates cam programs that turn ON and OFF at even intervals at particular
• The cam programs that turn ON/OFF at even intervals can be set from any angle (pulse start position).
Note 1. For pulse settings to be made, the resolution/(pulse number × 2) must be an integer. If this
Note 2. If the pulse number and pulse start position are set, a cam program that turns ON at the pulse
3-80
and then the data will resume flashing again.
bank and cam numbers.
12) are shown below.
For 360 resolution:
For 720 resolution:
If a pulse that falls between any of these pulse numbers is set, it will be converted to the next
largest pulse number. For example, if “7” is set for 720 resolution, it will be converted to “8.”
equation does not produce an integer, the pulse number will be changed to the nearest pulse
number that will give an integer. The pulse numbers are as follows:
start position will be created.
Output Tr:ON
1st digit display
Output Tr:OFF
1, 2, 3, 4, 5, 6, 9, 10, 12, 15, 18, 20, 30, 36, 45, 60, 90, 180
1, 2, 3, 4, 5, 6, 8, 9, 10, 12, 15, 18, 20, 24, 30, 36, 40, 45, 60, 72, 90, 120,
180, 360
Output Tr:ON
2nd digit display
Output Tr:OFF
1st digit display data
Output Tr:ON
3rd digit display
Output Tr:OFF
Output Tr:ON
4th digit display
Output Tr:OFF
Chapter 3
1st digit
Time
Time
Time
Time
Time