• The procedure for using the Cam Positioner at function level 2 (all functions) is outlined below.
1-12
Installation
Wiring
Power ON
Function level selection
Initial settings
Power resetting (OFF to
ON)
Parameter settings
Power resetting (OFF to
ON)
Creation and confirmation
of cam programs
Connection between
Resolver and machinery
Execution of origin
compensation
Teaching
Trial operation
Operation/monitoring
Origin shift execution
Compensation operation
Function level selection
S When using the teaching function.
S When making pulse output, cam data protect, output hold, one-direction function, and present
Procedure
value output settings.
Install the Cam Positioner according to the installation
environment conditions.
Connect the wiring for the power supply, Resolver, and
peripheral devices.
Before the power is turned ON:
• Check that the wires and connectors for the Resolver and
• Check that the Resolver and the machinery are not con-
After the power is turned ON:
• Check that there are no error codes displayed (E--**).
• Set the mode selection switch to RUN and check that the
Select function level 2 (all functions).
Set the resolution (SET mode) and rotation direction
(CW/CCW) to suit the application.
Turn ON the power to enable the set parameters.
Make the parameter settings.
Turn ON the power to enable the set parameters.
Create and check cam programs (PRGM mode).
Check the number of programs (SET mode).
Turn OFF the power and connect the Resolver and the
machinery.
Turn ON the power and execute origin compensation (use
the ADJ switch in SET mode).
If required, use the teaching function (SET mode) and create
a cam program while operating the machinery manually.
Change to PRGM mode, and, if required, adjust the cam
program while checking the timing of the cam output.
Change to RUN mode and check the operation of the
machinery and monitor the I/O status. Correct the cam
program if required (PRGM mode).
If required, turn ON TRIG input and execute origin shift
(RUN mode).
If required, adjust the cam program while checking the timing
of the cam output.
If required, set to function level 0 (monitor only) to prevent
faulty operation.
peripheral devices have been connected properly.
nected.
number of revolutions and the present angle display changes
when the Resolver axis is rotated by hand.
Contents
2-2
2-3
3-6-1
3-5-2
3-6-2 and 3-6-3
3-5-3
3-5-4
3-5-5
3-6-12
3-6-14
3-5-6
3-6-4
3-6-14
3-4
Chapter 1
Reference
section