Operation
H Cam Program Creation (PRGM Mode)
D Time Chart
The following shows how to create a cam program with the following kind of ON/OFF patterns.
The resolution is set to 360 (divisions/rotation) in this example. (When the resolution is set to 720, the
ON and OFF angle values will be double the values shown here.)
Bank No. 2
D Display and Operation Functions in PRGM Mode
Display Functions
Bank/Function display
Cam/Parameter No. display
SPEED/ON angle display
POSITION/OFF angle display
Before creating cam programs, use the information contained in 7-7 Cam Programming
Sheet to write down the ON/OFF patterns so as to make the process easier.
Function name
Cam
No.
ON
position
OFF
position
Displays the bank numbers currently being programmed.
Displays the cam numbers currently being programmed.
Displays ON angles or errors.
Displays OFF angles.
Time chart