3F88L-CR010C Omron, 3F88L-CR010C Datasheet - Page 111
3F88L-CR010C
Manufacturer Part Number
3F88L-CR010C
Description
CABLE RESOLVER FOR RS17/T 10M
Manufacturer
Omron
Datasheet
1.3F88L-RL10.pdf
(232 pages)
Specifications of 3F88L-CR010C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCR010C
- Current page: 111 of 232
- Download datasheet (5Mb)
Operation
H Origin Shift Execution (RUN Mode)
D Procedure
(Manual
operation of
the
machinery)
Origin shift
input (TRIG)
(After origin
shift has been
completed)
Operation
Display
Use the mode selection switch to change to RUN mode.
Rotate the machinery to the position to be set as zero (or to the origin
compensation value).
Turn ON the origin shift input (TRIG) to execute origin shift.
The absolute angle (Resolver’s electrical angle) will flash in the
POSITION/OFF display until origin shift has been completed.
The original display will appear when origin shift has been completed.
The speed display will be “0” and present angle will be “0” if the
machinery is not operating.
24 V DC
Explanation
Turn ON origin shift
input (TRIG)
Chapter 3
3-59