Operation
H Related Parameters (SET Mode)
D Advance Angle Compensation Value 1
D Advance Angle Compensation Value 2
• Use these parameters to set the Resolver speed and advance angle amount.
• The Resolver speed (r/min) is set as the speed data and the compensation amount is set as the angle
• The factory settings for both speed and angle data is “0.”
Note 1. The data for 720 resolution (divisions/revolution) is shown in parentheses.
Note 2. When the speed data is set to “0,” the angle data can only be set to “0.”
Note 3. The same speed data cannot be set for advance angle compensation values 1 and 2, unless
Note 4. These parameters are enabled by turning OFF the power supply and turning it ON again.
D Advance Angle Compensation Value 3
• Use this parameter to set the point to change the angle based on the advance angle compensation.
• The factory setting is “0.”
Note 1. The data for 720 resolution (divisions/revolution) is shown in parentheses.
Note 2. Set advance angle compensation value 3 in a section where the cam output does not change.
Note 3. These parameters are enabled by turning OFF the power supply and turning it ON again.
Function
No.
Function
No.
Function
No.
data.
S Make sure that the machinery is operating normally.
For example, if the advance angle amount changes from “0” to “1,” the angle must increase by “1”
somewhere in the rotation. This parameter sets the position for that change. The advance angle
amount is updated when the Resolver angle matches advance angle compensation amount 3.
the settings are “0.”
(Set in the middle of a section where ON or OFF status continues for a long time.) If cam out-
puts with short ON/OFF durations are set near advance angle compensation value 3, cam
outputs may not be made (if the advance angle amount is increasing) or may be output twice
(if the advance angle amount is decreasing).
b (
b (
b (
b
b
b
)
)
)
Parameter
No.
Parameter
No.
Parameter
No.
3
4
5
Setting range Speed data : 0 to 1600 (800)
Setting range Speed data: 0 to 1600 (800)
Setting range 0 to 359 (0 to 719) (see note 1)
(see note 1)
Angle data: 0 to 359 (719) (see
note 1)
(see note 1)
Angle data: 0 to 359 (719) (see
note 1)
Function level
Function level
Function level