Operation
5-1
H Errors Codes and Countermeasures
Note The “F” mark in the cam output column indicates that cam outputs are turned OFF regardless of
5-2
E-00
Error
code
the output hold settings. The “f” mark indicates that if output hold is set, the output status immedi-
ately before the error was generated will be maintained. If output hold is not set, cam outputs will
be turned OFF. (Refer to 3-6-9 Output Hold Function for information.)
If the 3F88L-160/162 Cam Positioner detects an error, the error code (E-**)will appear in
the SPEED/ON display. All control outputs (RUN, M⋅DET, ERROR) will turn OFF. The
cam output will vary depending on the output hold function settings.
The Cam Positioner errors will be detected during the following processes.
If an error code is displayed, determine the cause and take appropriate countermea-
sures.
S At power ON: Hardware check, program check, and power interrupt check during pro-
S During operation: Error check in RUN mode.
S During programming: ON region duplication errors in PRGM mode, cam data protect
S While setting parameters: Communications error checks in SET mode.
Diagnosis using Error Codes
gram write/save.
input prohibit checking, etc.
Hardware
failure
Error name
Memory
read/write
check error
when power
turned ON.
Description
F
output
Cam
Malfunction
due to noise
(system
recovers when
power is
turned ON
again.)
The Cam
Positioner is
malfunctioning
(system does
not recover
when power is
turned ON
again.)
Probable
cause
Check if noise has
been generated
when or after the
power was turned
ON and take
appropriate
countermeasures
against the noise.
Replace the Cam
Positioner.
Possible solution
Chapter 5
Turn the
power ON
again.
---
Error reset
method