Operation
Operation
• When the backlash compensation value (Function No. b, Parameter No. 2) is displayed, the present
• Use the Forward, Up, and Down Keys to change the data.
• Press the Set Key and the data will remain lit for approximately one second, the setting will be con-
• If the data is inappropriate and the Set Key is pressed, all displays will flash twice and then return to the
• Press the Clear Key to return the data to the factory settings. If the Clear Key is pressed, the three
D Backlash Compensation Enable/Disable
• Set this parameter to “1” to enable backlash compensation. (0: backlash compensation disabled;
• The factory setting is “0.”
Note This parameter is enabled when the power is turned OFF and then turned ON again.
Operation
Function
No.
setting will be displayed in the SPEED/ON display and the first digit (rightmost digit) will flash.
firmed, and the display will resume flashing.
settings before the data was edited. Re-input the correct data.
digits of data will start flashing. Press the Set Key while the data is flashing and the display will change
to “-- -- --” and the factory settings will be restored. If the Clear Key is pressed again while the three digits
of data are flashing, the data will not be initialized and the display will return to the edited state.
1: backlash compensation enabled)
Various compensation value
enable/disable setting
H (
h
Use the mode selection switch to change to SET mode.
Use the mode selection switch to change to SET mode.
)
Backlash
compensation
enable/disable
Origin
compensation
value
Parameter
No.
1
Backlash compensation value
Advance angle compensation
enable/disable
Setting range 0, 1
Baud rate
Present value
output setting
Function level
Chapter 3
3-61
2