Operation
Operation
Outline for Setting and Releasing Cam Protect
Change to SET mode (using the mode selection switch)
Set the cam protect function number
Press the Set Key (enabling bank number selection)
Set the bank number to which cam protect is to be set or
cleared.
Press the Set Key (enabling cam protect settings).
Set or release cam protect.
Confirm settings
Press the Clear Key (enables bank number selection).
Press the Bank/Function Key (enables function number
settings).
Use the Bank/Function Key to set function number C.
The Bank/Function display will start flashing.
”C” will appear in the leftmost Bank/Function digit.
Use the Up and Down Keys to set the bank number.
The Bank/Function numeral will increase or decrease
as these keys are pressed.
The cam number will appear in the Cam/Parameter No.
display.
There are two ways to set or release cam protect.
• Setting/releasing by bank
• Setting/releasing by cam
Once cam protect has been set/cleared for one bank,
press the Set Key and save the setting. “C” will flash
twice to confirm the settings have been saved.
The cam protect settings can be adjusted again if
required.
The Bank/Function display will flash.
The Cam/Parameter No. display will turn OFF.
The operation to set or release cam protect has now
been completed.
Up + ON/OFF Switching Keys: Sets cam protect for all
cams in the bank.
Down + ON/OFF Switching Keys: Releases cam pro-
tect from all cams in the bank.
Use the Cam/Parameter Key to set the cam number,
and then press one of the following.
Up Key: Sets cam protect for the specified cam.
Down Key: Releases cam protect for the specified cam.
Cam protect
If setting or clearing
cam protect for other
bank numbers.
Chapter 3
3-71