Specifications of MPR121QR2

Number Of Inputs/keys
12 Key
Data Interface
I²C, Serial
Voltage - Supply
1.71 V ~ 3.6 V
Current - Supply
29µA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-UQFN, 20-µQFN
Output Type
Logic
Interface
I²C
Input Type
Logic
Supply Voltage
2.5 V to 3.6 V
Dimensions
3 mm L x 3 mm W x 0.65 mm H
Temperature Range
- 40 C to + 85 C
Termination Style
SMD/SMT
Supply Current
29µA
Ic Interface Type
I2C
Supply Voltage Range
1.71V To 3.6V
Sensor Case Style
QFN
No. Of Pins
20
Operating Temperature Range
-40°C To +85°C
Interface Type
I2C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MPR121QR2
MPR121QR2TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPR121QR2
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MPR121QR2
0
MPR121
20
Table 18. ELE0-7 Out Of Range Status Register Field Descriptions
Field
E7S
E6S
E5S
E4S
E3S
E2S
E1S
E0S
7
6
5
4
3
2
1
0
Electrode 1 OOR Status – The Electrode 7 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 0 OOR Status – The Electrode 7 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 7 OOR Status – The Electrode 7 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 6 OOR Status – The Electrode 7 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 5 OOR Status – The Electrode 7 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 4 OOR Status – The Electrode 7 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 3 OOR Status – The Electrode 7 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 2 OOR Status – The Electrode 7 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Description
Freescale Semiconductor
Sensors

Related parts for MPR121QR2