MPR121QR2 Freescale Semiconductor, MPR121QR2 Datasheet - Page 24

IC CTLR TOUCH SENSOR 20-QFN

MPR121QR2

Manufacturer Part Number
MPR121QR2
Description
IC CTLR TOUCH SENSOR 20-QFN
Manufacturer
Freescale Semiconductor
Type
Capacitive, Proximity Sensorr
Datasheet

Specifications of MPR121QR2

Number Of Inputs/keys
12 Key
Data Interface
I²C, Serial
Voltage - Supply
1.71 V ~ 3.6 V
Current - Supply
29µA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-UQFN, 20-µQFN
Output Type
Logic
Interface
I²C
Input Type
Logic
Supply Voltage
2.5 V to 3.6 V
Dimensions
3 mm L x 3 mm W x 0.65 mm H
Temperature Range
- 40 C to + 85 C
Termination Style
SMD/SMT
Supply Current
29µA
Ic Interface Type
I2C
Supply Voltage Range
1.71V To 3.6V
Sensor Case Style
QFN
No. Of Pins
20
Operating Temperature Range
-40°C To +85°C
Interface Type
I2C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MPR121QR2
MPR121QR2TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPR121QR2
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MPR121QR2
0
MPR121
24
Note: In most cases the CDT in this register is not used. It will normally be auto-configured as described in AN3889
average current consumption of the device.
in a very low average current consumption.
While the 1 ms to 128 ms does affect the filtering, the main purposed of adjusting the sample rate would be to change the
From this, it can be seen that the 12 μs up time from the 1 ms samples results in a very low percent of duty cycle. This results
0
Table 21. Filter Configuration Register Field Descriptions
First Filter
Field
CDT
ESI
SFI
7:5
4:3
2:0
1 ms
Charge Discharge Time – The Charge Discharge Time field selects the amount of
time an electrode charges and discharges.
000 Encoding 0 – Invalid
001 Encoding 1 – Time is set to 0.5 μs
010 Encoding 2 – Time is set to 1 μs
~
111 Encoding 7 – Time is set to 32 μs.
Second Filter Iterations – The Second Filter Iterations field selects the number of
samples taken for the second level filter.
00 Encoding 0 – Number of samples is set to 4
01 Encoding 1 – Number of samples is set to 6
10 Encoding 2 – Number of samples is set to 10
11 Encoding 3 – Number of samples is set to 18
Electrode Sample Interval – The Electrode Sample Interval field selects the period
between samples used for the second level of filtering.
000 Encoding 0 – Period set to 1 ms
001 Encoding 1 – Period set to 2 ms
~
111 Encoding 7 – Period set to 128 ms
Figure 22
illustrates this adjustment.
Figure 22.
TIME (ms)
2 ms
Description
3 ms
Freescale Semiconductor
Sensors

Related parts for MPR121QR2